IOMM
Display
Message
DC Line Open
Duplicate
Module IDs
Factory Data
Not Set
Fan Speed Low
Fan Speed Too
Low
Module General
Fault
Module High
Temperature
Module Memory
Issue
Module OCP
Tripped
MODULE
OVER TEMP
(Module /
Charger Over
Temperature)
Webasto Charging Systems, Inc.
Message
Description
type
The difference between the
module reported voltage
Fault
and local battery voltage
exceeds 5 volts.
At least two modules have
Fault
duplicate CAN IDs on the
internal CAN bus.
The charger factory
Fault
configuration is missing.
Warning
The fan speed is very low.
The fan has stopped or is
Fault
too low to charge.
The module faulted with no
Fault
specific reason reported.
The module temperature is
Warning
very high
The module had a memory
Fault
related error.
There was an error in the
Fault
over-current protection
module.
The air intake is blocked.
The system board
temperature sensor is
above 80° C.
Fault
The module temperature is
too high to charge.
The module failed.
ProCore Edge North America
Action(s)
Check the battery voltage
sensor wiring for damage.
Call Webasto service.
Call Webasto service.
Call Webasto service.
Call Webasto service.
Call Webasto service.
Check for obstructed air
flow.
Call Webasto service.
Check that the battery
voltage is within range for
the charger.
Check for obstructed air flow.
Remove the blockage.
Replace the power module.
63 of 68
31241-03-0202