Descargar Imprimir esta página

Anest Iwata GRAVITY Serie Manual De Instrucciones De Uso Y Mantenimiento página 2

Ocultar thumbs Ver también para GRAVITY Serie:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 7
AZ3 HTE S Impact | AZ3 HTE S HVLP Impact
COMPLIANCE TO STANDARD OF SPRAY GUN
AIRGUNSA Spray Guns comply with 2014/34/EU Directive relating to equipment and protective systems intended for
use in explosive potentially atmospheres.
COMPLETE COMPLIANCE MARKING:
ABBREVIATE MARKING
ON THE SPRAY GUN:
TECHNICAL DATA
model name
ø mm
1.2
1.3
1.4
AZ3 HTE-S IMPACT
1.6
1.8
2.0
1.3
1.4
1.5
AZ3 HTE-S HVLP IMPACT
1.6
1.8
2.0
The HVLP spray guns follows all compliance HVLP mandates. Follow the indication of the inlet air pressure to achieve atomizing pressure of
0.7 bar at the center of the air cap.
2
II 2 G Ex h IIB T6 Gb X +5°C ≤ Ta ≤ + 40°C
II 2 G Ex h X
II 2 G Ex h X
II 2 G Ex h X
bar*
cap
ml/min
Nl/min
250
HTE-S1
275
375
290
2.5
300
HTE-S2
335
362
375
144
HVLP 1
1.8
159
307
174
176
HVLP 2
2.1
198
369
222
AZ3 HTE S Impact | AZ3 HTE S HVLP Impact
AIRGUNSA spray gun, has been designed for the application of
paints, lacquers and other products that can be atomized by means
of compressed air, on all surfaces suitable to receive this type of
treatment.
Before use, adjustment or maintenance, it is important to read
this instruction manual very carefully. This manual must be
stored in a safe place for any future reference.
These AIRGUNSA Spray Guns comply with 2014/34/EU Directive relating
to equipment and protective systems intended for use in explosive
potentially atmospheres.
ABBREVIATE MARKING
ON THE SPRAY GUN:
ALWAYS observe WARNINGS and CAUTIONS in this instruction
manual.
Symbol
WARNING
Hazard level
WARNING
Potentially hazardous
situation
mm (in)
CAUTION
Potentially hazardous
190
situation
210
IMPORTANT
Potentially hazardous
situation
230
1. TECHNICAL SPECIFICATIONS
250
Max. working air pressure:
270
Weight g (lbs): (without cup)
Noise level (LAeqT)*:
280
Air Connection:
300
Fluid Connection:
320
Max. Temperature range:
Atmosphere 5 ~ 40 °C / Air-Fluid 5 ~ 43 °C
260
* Measuring point: 1m backwards from gun, 1.6 m height.
280
2. SAFETY WARNING
300
FIRE AND EXPLOSION
1. Never use the following HALOGENATED HYDROCARBON SOLVENTS:
which can cause cracks or dissolution of gun body (aluminium) due to
chemical reaction. UNSUITABLE SOLVENTS: methyl chloride, dichloromethane,
1.2-dichloroethane, carbon tetrachloride, trichloroethylene,
1.1.1-trichloroethane
2. Sparks and open flames are strictly prohibited. Paints can be highly
flammable and can cause fire. Do not expose to open flames, electrical
goods, cigarettes etc.
3. Securely ground spray gun using conductive air hose. (<1MΩ) Always
ensure that the spray gun is earthed correctly.
PROTECTION OF HUMAN BODY
1. Use in a well-ventilated site, using a spray booth.
Poor ventilation can cause organic solvent poisoning and fire.
2. Always wear protective gear (safety glasses, mask, gloves) to avoid
inflammation of eyes and skin.
In case of any physical discomfort, immediately seek medical advice.
3. The noise level of AIRGUNSA Spray Gun doesn't exceed the 85 dB (A)
A-weighted sound pressure value about the risk of daily exposure to noise.
The use of individual hearing protection is always recommended, because
the terms of use and the influence of other noises in the job area, could increa-
se the average value allowed.
4. Pulling the trigger many times during operation, may cause carpal
tunnel syndrome. Always rest, in case of tiredness.
IMPROPER USE
1. Never point gun towards people or animals.
2. Never exceed maximum working pressure or maximum operating
Temperature
3. Always release air and fluid pressure before cleaning, disassembling
or servicing. Otherwise, remaining pressure can cause bodily injury due to
improper operation or scattering of cleaning liquid.
4. Tip of fluid needle set has a sharp point.
Do not touch the tip during maintenance to avoid accidents.
II 2 G Ex h X
5. Never use this gun to spray foods or chemicals. Otherwise, foreign sub-
stance, could cause corrosion of fluid passages which could adversely affect
health.
6. Never alter this spray gun, to avoid insufficient performance and damage.
Consequence
7. If something goes wrong, immediately stop operation and find the cause.
Death or serious injury
Do not use again, until you have solved the problem.
8. Do not enter working areas, where robots, reciprocators, etc. are used,
Minor to moderate injury
until they have been turned off. Otherwise, they could cause injury.
Property damage
3. HOW TO CONNECT
CAUTION
7.0 bar (100 PSI)
517 (1.14)
-
Use clean air filtered through air dryer and air filter.
77.6 dB(A)
-
When using this gun for the first time after purchase, adjust fluid needle
G1/4"M
packing set, spray cleaner to clean fluid passages and remove rust pre-
ventive oil.
G1/4"F
-
Firmly fix cup to spray gun, to avoid that disconnection of it, can cause
bodily injury.
1. Firmly connect an air hose to air nipple G1/4" (17).
2. Firmly connect a suitable cup to fluid nipple G1/4".
3. Flush fluid passages with a compatible cleaner.
4. Pour paint into container, test spray, adjust fluid output and pattern width.
4. HOW TO OPERATE
_
Suggested atomizing air pressure varies according to each model, and it is
listed in the Technical Data table.
_
Paint viscosity differs according to paint property and painting conditions,
12 to 23 sec. / Ford cup#4 is recommended.
_
Set the spray distance from the gun to the work piece, as near as possible
within the range of 100-200 mm (3.9-7.9 in).
_ The gun should be held so that it is perpendicular to the surface of the
workpiece at all times. Then, the gun should move in a straight and horizon-
tal line. Arcing the gun causes uneven painting.
EN
3

Publicidad

loading

Este manual también es adecuado para:

Gravity az3 hte sGravity az3 hte s hvlp