9.2 Controller Setup
1. Power on the controller by activating the appropriate mains supply. The POWER LED will illuminate.
2. Press the ON and OFF buttons together until the CALIBRATION LED illuminates.
3. Press the ON button to change the pump model. Refer to Section 10.2.1 for options. The default mode is dependent on the product
number.
4. Press the ON and OFF button to complete setup until only POWER LED is lighted.
9.2.1 Model Selection
Model
VR050 24 VDC
VR050 24 VDC
VR100 24 VDC
VR100 24 VDC
VR050 12 VDC
VR050 12 VDC
9.2.2 Controller Limits
Type
Over Voltage
Under Voltage
Over Current
Under Current
Run Dry
Over Temperature
Over Runtime
9.3 Completion
Power up the equipment and check for correct operation. This is achieved by pressing the ON button on the controller, or where a controller
isn't supplied, activating the mains supply.
a.
Priming may take up to 45 seconds.
b.
The equipment should stabilise within 30 seconds of initial priming.
c.
The equipment does not function as expected, discontinue use and refer to Section 15 for troubleshooting.
Switch Type
Power
NO
NC
NO
NC
NO
OFF
NC
OFF
VR050 24V
28 VDC
19 VDC
16 A
2 A
5 A
85ºC
30 Minutes
Run
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
ON
Limits
VR100 24V
28 VDC
19 VDC
24 A
2 A
8 A
85ºC
30 Minutes
8
LED
Fault
ON
OFF
ON
OFF
ON
OFF
Time to Occur
VR050 12V
14.8 VDC
9 VDC
24 A
2 A
8 A
85ºC
30 Minutes
Calibration
ON
ON
ON
ON
ON
ON
(Seconds)
5
5
2
2
10
2