Additionally Required Materials
Additionally Required Materials / Zusätzlich erforderliche Materialien / Matériaux
supplémentaires requis / Materiales adicionales necesarios / Materiais Adicionais
Necessários / Extra benodigde materialmen / Materiali aggiuntivi necessary / Materiały
wymagane dodatkowo / Další požadované materiály / Ytterligare materialkrav /
Materiale suplimentare necesare / Други необходими материали / Yderligere
nødvendige materialer / Πρόσθετα απαιτούμενα υλικά / Täiendavad vajalikud materjalid
/ Muut vaaditut materiaalit / Potrebni dodatni materijali / További szükséges anyagok
/ Papildomos reikalingos medžiagos / Papildus vajadzīgie materiāli / Dodatočne
požadované materiály / Dodatno zahtevani materiali / Ayrıca gerekli malzemeler /
Materiais adicionais necessários / ‫المواد المطلوبة أيض ً ا‬
• Battery
No.
Required Material
1
Protective pipe
• Inverter
No.
Required Material
1
PV wire
2
Communication wire
3
Protective pipe
Grid Wire and Breaker Recommended
Model
X3-IES-4K X3-IES-5K X3-IES-6K X3-IES-8K X3-IES-10K X3-IES-12K X3-IES-15K
Five-
core wire
4~6 mm² 4~6 mm² 4~6 mm²
(copper)
Breaker
20 A
EPS (Off-grid) Wire and Breaker Recommended
Model
X3-IES-4K X3-IES-5K X3-IES-6K X3-IES-8K X3-IES-10K X3-IES-12K X3-IES-15K
Five-
core wire
4~6 mm²
(copper)
Breaker
16 A
* It is recommended that the outer diameter of Grid and EPS cables be 17.5~18.5mm or
19~21 mm. The electrical connection method of Grid and EPS cables with different outer
diameters differ.
* Note: For a 4.0 ~ 8.0 kW inverter, please select suitable AC ferrules from the inverter
accessory pack in accordance with the diameter of the Grid and EPS cables actually used.
* The parameters have some differences because of different environment and material.
Please choose appropriate cable and micro-breaker according to the local conditions.
• X3-Matebox G2
No.
Required Material
1
Grid cable
2
Load cable
3
Protective pipe
Type
Corrugated pipe
Type
6 mm² dedicated PV wire
with a voltage rating of
1000 V, a temperature
resistance of 105℃ , a fire
resistance grade of VW-1
Network cable CAT5E
White corrugated pipe
20 A
20 A
4~6 mm²
4~6 mm²
16 A
16 A
Type
Five-core copper cable
Four-core copper cable
White corrugated pipe
External diameter: over 67.2 mm
Conductor Cross-section
External diameter: over 67.2 mm
4~6 mm²
6 mm²
32 A
40 A
4~6 mm²
6 mm²
20 A
25 A
External diameter: over 67.2 mm
Diameter
6 mm²
0.2 mm²
6 mm²
6 mm²
40 A
40 A
6 mm²
6 mm²
32 A
32 A
Diameter
14 mm²
14 mm²
115