• Battery
No.
Mode
1
Startup
2
Shutdown
3
Standby
4
Charging
5
Discharging
6
Fault
7
Working
B+
COM
HEAT
B-
Press and hold the BAT BUTTON for about 1 to 2 seconds to
activate the system, at this point, the status light flashes a yellow
light every 0.1 seconds until finishing self test, of which the period
lasts about 3 to 4 seconds. Then the status light flashes green
light every 0.5 seconds after finishing self test. During the whole
period, all the SoC power indicators were off. After successful
communication to the inverter, the status light turns solid green
light, and SoC power indicators come on solid green light based on
the actual remaining capacity.
After pressing and holding the BMS BUTTON for more than 1
second, the status light comes on solid green light, and the SOC
power indicators flash blue in turn. Then all lights are off within 2.4
seconds after releasing the button.
The status light flashes green for 1 second and turns off for 4
seconds. The SOC power indicators are off.
The status light comes on solid green light, and the state of SOC
power indicators depends on the actual situation. For details, please
refer to the User Manual .
The status light comes on solid green light, and the state of SOC
power indicators depends on the actual situation. For details, please
refer to the User Manual .
In case of failure, the status light will remain on solid red light for
10 minutes, and then such red light will flash for 1 second and then
turn off for 4 seconds.
In case of warning, the status light will flash yellow light for 1
second, and then turn off for 4 seconds.
B-
25%
50%
75%
100%
SOC1 SOC2 SOC3 SOC4
Description
Status