2. INSTALLATION
2.1. Important prior precautions
Before installing the equipment, follow the instructions below:
The Poolsquad iPO production must be adapted to the volume of the pool to be treated, the use of the pool,
the presence of any neighbouring equipment (infinity edge, reflecting pool, slide, etc.), as well as the weather
conditions at the installation site.
Use water from a softener connected to the mains water network. Prohibit the use of any naturally sourced
water (rain, run off, lake, well), at the risk of prematurely damaging the electrolysis cells and the water
softener.
The iPO must be installed in a closed, dry and sufficiently ventilated room, out of reach of from splashes and
water projection, and away from UV radiation. The ambient temperature inside this room must not exceed
45°C.
If this room is in a country with a hot and damp climate, it must be air-conditioned.
It this room is in a country with a temperate climate, it must have mechanical ventilation.
Determine a specific location to install the system, taking its size into account. Also provide for an additional
space around the installation, in order to make access to this easier for maintenance operations.
The apparatus must be installed level, on a flat floor and on a stable surface.
The pH corrector container must be kept 2 metres away from any electrical device or any other chemicals. In
order for acid fumes to be expelled outside the pool house, a venting system must be placed on the pH
possibly resulting in complete device failure. Personal protective equipment (glasses with side protection,
the injection circuit.
The salts authorized with our devices must be stamped according to one of these 4 Standards (EN 14805, EN
16370, EN 16401 or EN 973), otherwise the warranty will be canceled.
and evacuated.
If the pool house is served by gravity fed drains (for example: semi-underground or underground room),
an evacuation system with a lifting pump must be installed.
It is imperative that this lifting pump:
- has a minimum flow 2 times greater than the maximum water flow of the network.
- be cabled to an electrical supply independent of that for the equipment (in order to maintain pump
operation in the event the electricity supply to the equipment is cut off or disconnected).
For a water softener, ensure that the electrical transformer supplied with the softener is out of reach of
splashes and any contact with the water.
-offs (water softener, overflow) are watertight, correctly connected