3.8. Safety devices
3.8.1.
Overwintering mode
Overwintering mode is deactivated by default.
The overwintering mode can be activated from the alarms menu and allows for stopping chlorine production
when the swimming pool temperature is below 15°C.
When overwintering mode is on:
o It displays instantly on the screen.
o Overwintering mode starts and stops automatically.
3.8.2.
Alarms and alerts
DEFAULT
CONFIGURATION
ALARMS
Activated
ALERTS
* The corresponding alarm or alert is maintained while the detected fault remains in place, and the corresponding
message reappears a few moments after dismissal.
IMMEDIATE AUTOMATIC
MESSAGE
DISPLAYED/FAULT
DETECTED
Production
AUTOMATIC OPERATION(S)
Message
displayed
STOP
pH
regulation
No
Yes
Yes
No
Yes
No
UPON ACTIVATION
Immediate stop of production
and/or pH regulation
Yes
No
POSSIBLE CAUSE
pH corrector container
empty
Unadjusted free chlorine
rate measurement
Incorrect or defective
amperometric probe
electrical connection
Amperometric probe
defective or at the end of
its life
DISMISSAL*
Press the OK or
or press and hold, depending
whether it is alarm or alert).
VERIFICATIONS AND
SOLUTIONS
Replace the pH corrector
container.
Carry out an adjustment of the
free chlorine rate
measurement.
Check that:
- the amperometric probe
connection to the
electronic unit.
- the condition of the
amperometric probe cable.
- internal wiring to the
amperometric probe.
- the state of the terminal
block internal to the
amperometric probe.
Change the amperometric
probe.
button (press
OPTION TO
DEACTIVATE
Yes
Yes
No
19