3. Remove the dipstick. Wipe it dry with a clean cloth and
completely reinsert it into the dipstick tube.
DO NOT overfill the engine with engine oil. Damage to the
engine may occur.
4. Install the dipstick.
5. Remove the dipstick. The oil level should be at the FULL
mark. If necessary, add oil. DO NOT overfill.
6. Put the aXis Controller
®
MANUAL or AUTO for example).
Changing the Engine Oil
Always wear protective glasses or goggles and protective
clothing when changing hot engine oil.
Always be environmentally responsible. Consult the local
authorities or reclamations facility for proper disposal of
engine oil waste.
1. Press the MAN (Manual) button on the aXis Controller
start and run the HSB.
2. Allow the engine to run until it reaches operating temperature.
WARNING
in the previous position (either
WARNING
NOTICE
®
3. Press the OFF button on the aXis Controller
4. Remove the fuse from the front of the aXis Controller
will disable automatic starting in the event of a power outage.
5. Put the generator ON/OFF switch to the OFF position.
6. Remove oil drain hose (A) from oil hose clamp (B) holding it
and remove oil drain cap (C) on the HSB enclosure front.
A. Oil Drain Hose B. Oil Hose
7. Push the drain hose through the hole where the oil drain cap
(A) was on the HSB enclosure front. Position hose over a
suitable drain pan (B). Unscrew oil drain hose cap (C) from oil
drain hose.
A
A. Oil Drain Cap
8. Allow crankcase to empty.
to
®
29
MAINTENANCE
.
®
A
C
C. Oil Drain Cap
Clamp
B
B. Oil Drain Pan
C. Oil Drain Hose Cap
. This
®
B
C

Publicidad

loading