Mechanical Specifications; Electrical Specifications - BFT LINEA 1 Instrucciones De Uso Y De Instalacion

Automatizaciones para puertas
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 44
ENGLISH
Thank you for buying this product, our company is sure that you will be
more than satisfied with its performance.
This product is supplied with a "Warnings" leaflet and an "Instruction Manu-
al". These should both be read carefully as they provide important informa-
tion about safety, installation, operation and maintenance.
This product complies with recognised technical standards and safety re-
gulations. We declare that it is in conformity with the following European
Directives: 89/336/EEC, 73/23/EEC, 98/37/EEC (and subsequent amend-
ments).
1) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
• The "Warnings" leaflet and "Instruction booklet" supplied with this pro-
duct should be read carefully, as they provide important information about
safety, installation, use and maintenance.
• Scrap all packing materials (plastic, cardboard, polystyrene etc) accor-
ding to the provisions set out by current standards. Keep nylon or polysty-
rene bags out of children's reach.
• Keep the instructions together with the technical brochure for future refe-
rence.
• This product was exclusively designed and manufactured for the use spe-
cified in the present documentation. Any other use not specified in this
documentation could damage the product and be dangerous.
• The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that ex-
pected and specified in the present documentation.
• Do not install the product in explosive atmosphere.
• The construction components of this product must comply with the fol-
lowing European Directives: 89/336/EEC, 73/23/EEC, 98/37/EEC (and
subsequent amendments). As for all non-EEC countries, the above-men-
tioned standards as well as the current national standards should be re-
spected in order to achieve a good safety level.
• The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing clo-
sing structures (door, gates etc.), as well as from any deformation which
might occur during use.
• The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC (and subse-
quent amendments).
• Disconnect the electrical power supply before carrying out any work on
the system. Also disconnect any buffer batteries, if provided. Once the
operator is reconnected to the power supply, check that the safety devices
work correctly.
• Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
• Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
• Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
• Fit all the safety devices (photocells, electric edges etc.) which are nee-
ded to protect the area from any danger caused by squashing, conveying
and shearing.
• Fix a Warning sign to the structure.
• The Company declines all responsibility with respect to automation safety
and correct operation when other manufacturers' components are used.
• Only use original parts for any maintenance or repair operation.
• Do not modify the automation components, unless explicitly authorised by
the Company.
• Instruct the product user about the control systems provided and the ma-
nual opening procedure in case of emergency.
• Do not allow persons or children to stand in the automation working
area.
• Keep radio control or other control devices out of children's reach, in order
to avoid unintentional automation activation.
• The user must avoid any attempt to carry out work or repair on the au-
tomation system, and always request the assistance of qualified person-
nel.
• Anything which is not expressly provided for in the present instructions, is
not allowed.
• Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.
• Check that the specified range of temperature is compatible with the pla-
ce where the operator is to be installed.
• Take care to avoid any possible crushing between moving parts and sur-
rounding fixed parts.
• If door opening is controlled by a fire alarm system, the closing operation
must be activated by means of a hold-to-run button.
22 -
LINEA 1-2 - Ver. 02
INSTALLATION MANUAL
• Lift the control device with equipment suitable for reducing manual load,
after taking care to check it for correct balancing.
• If present, the hold button must be fitted within sight of the door but away
from the moving parts, 1.5 m high and not accessible to the public.
• If the operator is fitted less than 2.5 m high, it is necessary to ensure an
adequate degree of protection for electrical and mechanical componen-
ts.
• The motor cannot be fitted on doors which incorporate pedestrians' doors
(unless the motor drive can work with the small door open).
• After completing the installation, ensure that the motor setting is correct
and the protection and release systems work correctly.
2) GENERAL OUTLINE
Warning: installation must be carried out by qualified personnel (qualified
installer).
Motor-driven top rail for automatic sliding doors with one (LINEA 1 mod.) or
two (LINEA 2 mod.) leaves.
Supplied with control panel. Accessories available for complete installation.
3) TECHNICAL SPECIFICATIONS
3.1) Mechanical specifications
LINEA 1 mod. doorway opening
LINEA 2 mod. doorway opening
Single-leaf capacity load
Double-leaf capacity load
3.2) Electrical specifications
Power supply
Fuses
Supply to accessories
Absorbed current (mains)
Opening speed
Closing speed
Automatic closing time
End-of-run speed
Temperature range
Operation cycle
Slow-down starting position Automatic
Braking
Antisquash
Emergency batteries
Protection
Top rail dimensions
(*) Special supply voltages on request.
4) IDENTIFICATION OF COMPONENTS (fig. 3)
The standard LINEA automation system comprises:
1
Bearing top rail in natural or anodised aluminium
2
Power supply unit provided with bipolar switch, mains fuse and anti-
interference filter.
3
ADLINEA microprocessor control unit.
4
Direct current gearmotor.
5
Optical encoder for stroke detection and obstacle control.
6
Driving pulley.
7
ISORAN RPP8 15EC Toothed towing belt
8
2 Carriages for leaf with 2 wheels on bearings, and an anti-derailment
roller, to be adjusted in height and depth.
9
Leaf fixing contour.
10 Rubber end-of-stroke door stops.
The following accessories are available to complete the installation:
11 DAB1
12 NCE
13 PFD
14 NTS
15 PGI
16 PPR
17 RIP
18 FPA1
FPA2
19 CRTL
20 SASAM1-2 Leaf break-open device
5) TYPES AND METHODS OF DOOR MOUNTING
WARNING: This operation should only be carried out by qualified per-
sonnel.
The LINEA automation system cannot be installed outdoors.
750mm min 2500mm max
800mm min 2900mm max
LINEA 1 mod. 150 kg
LINEA 2 mod. 120+120 kg
230V~ (±10%) 50Hz
see fig. 22
24V~= 0.4A max
1A
can be set up to 90 cm/s (LINEA 1)
can be set up to 180 cm/s (LINEA 2)
can be set up to 35 cm/s (LINEA 1)
can be set up to 70 cm/s (LINEA 2)
can be set from 1 to 60s
from 5 to 10cm/s in automatic (LINEA 1)
from 10 to 20cm/s in automatic (LINEA 2)
0°C to + 50°C (inside casing)
Continuous at 25°C
Adjustable
Antisquash safety in presence of obstacles
(optional) 2 x 12V 1.2Ah
IP X0
see (fig.1)
Battery-operated antipanic device
Electromagnetic latch and manual release
Digital function pushbutton panel
Support rail in anodised or natural aluminium
Lower door-guide contour for framed leaves
Runner for lower door guide
Infrared radar with short-range operation
Photocells (1 amplifier, 1 transmitter, 1 receiver)
Photocells (1 amplifier, 2 transmitters, 1 receivers)
Closing guard

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Linea 2

Tabla de contenido