Supply line terminal strip
Number of terminals
Conductor material
Clamping range [mm²]
Tightening torque [Nm]
Enable input terminals
Number of terminals
Specification of the external switching contact
Clamping range [mm²]
Tightening torque [Nm]
Downgrade input terminals
Number of terminals
Specification of the external switching contact
Clamping range [mm²]
Tightening torque [Nm]
Switching output for shunt release terminals
Number of terminals
Max. switching voltage [V] AC
Max. switching voltage [V] DC
Max. switching current [A]
Clamping range [mm²]
Tightening torque [Nm]
rigid
flexible
with ferrule
rigid
flexible
with ferrules
rigid
flexible
with ferrules
rigid
flexible
with ferrules
5
Copper
Min.
Max.
0.2
10
0.2
10
0.2
6
0.8
1.6
2
Potential-free (NO)
Min.
Max.
0.2
4
0.2
2.5
0.25
2.5
0.5
0.5
2
Potential-free (NC or NO)
Min.
Max.
0.2
4
0.2
2.5
0.25
2.5
0.5
0.5
2
230
24
1
Min.
Max.
0.2
4
0.2
2.5
0.25
2.5
0.5
0.5
EN