1 "6.4 Testing the product" [} 22]
u Switch on the power supply and check.
6.4
Testing the product
The tasks described in this section may only
be carried out by a qualified electrician.
u At initial start-up, test the product in accordance
with IEC 60364-6 and the applicable national
regulations (e.g. in Germany: DIN VDE
0100-600).
The test can be carried out in conjunction with the
MENNEKES test box and standard-compliant test
equipment. The MENNEKES test box simulates
vehicle communication. Test boxes are available as
an accessory from MENNEKES.
6.5
Description of the configuration tool
The basic settings can be made via DIP switches at
the charging station. The configuration tool is re-
quired for advanced settings.
On initial commissioning, on our website
under "Services" > "Software updates",
check whether there is a newer firmware
version of the product or configuration tool.
Update if necessary.
1 "8.3 Firmware update" [
22
 27]
}
The following advanced settings can be made:
n Perform firmware update
n Change the default setting (20 A) for the unbal-
anced load limitation (possible values:
10 A ... 30 A)
n Deactivate acoustic feedback
n Deactivate energy-saving mode (for reduced
standby consumption)
n Activate undervoltage / overvoltage detection
for the connected phases and set the respect-
ive limit values
n Import and export settings
n Set the overcurrent fault trip tolerance (default:
standard tolerance)
n Change the logic of the downgrade input (de-
fault: downgrade is active when the switching
contact is closed)
n Adjust the colour settings of the LED status dis-
play
n Convert the enable input to a pulse signal
In addition, the current operating values are dis-
played and the DIP switch settings are explained in
the configuration tool. Should a fault occur, the con-
figuration tool offers assistance with troubleshoot-
ing (fault message, log file).
To use the configuration tool, the MEN-
NEKES configuration cable is required. You
can find the MENNEKES configuration cable
(order number 18625) on our website under
"Products" > "Accessories". You can also
download the configuration tool and in-
struction manual there.
1 "1.1 Website" [
The instruction manual for the configuration tool
describes how to install and use the tool.
1 Comply with the configuration tool manual.
 2]
}

Publicidad

loading