3. Remove the screws on the bottom of the Seal Bar.
4. Remove sealing wires.
5. Remove Teflon tape from sealing bar and clean the bar
with a lint-free cloth.
6. Cut a piece of replacement Teflon tape the length of the
Sealing Bar, then apply the tape to the bar.
7. Cut new sealing wire(s) to the length of the Sealing Bar
plus about 6" (15 cm) and attach one wire to one side of
the Seal Bar by tightening the screw.
8. Pull the wire across the Sealing Bar straight and tight,
then attach it by tightening the screw.
9. Repeat steps 7 & 8 for the second wire, then trim wires.
10. Cut a piece of Teflon tape the same length of the sealing
bar, plus about 2" (5 cm).
11. Apply the tape smoothly over the sealing wires on the
Sealing Bar; trim tape.
12. Place Sealing Bar back in the machine by snapping it into
the holder; verify the bar is properly secured.
Replacing the Seal Pad
If the any part of the Seal Pad is rough, replace it.
Supplies and Tools:
• Replacement Seal Pad
• Scissors
1. Remove the worn pad from the holder.
2. Cut a new piece of Seal Pad that is the same size and
shape as the old one; this helps avoid sealing issues.
3. Place the new pad in the holder so it is completely in the
groove, as evenly as possible.
5
Replacing the Lid Gasket
The lid gasket ensures the vacuum chamber is completely
sealed during the packing cycle. This is essential to achieve
maximum vacuum. The lid gasket wears due to the extreme
pressure differences and must be replaced regularly.
Supplies and Tools:
• Replacement Gasket
• Scissors
1. Remove the worn gasket.
2. Cut a new piece of gasket slightly longer than the old one.
3. Position the new gasket so the lip faces down and out,
4. Cut gasket straight across so ends come together tightly
Vacuum Packing Machine Dual 16" Sealing Bars
then press the gasket into the slot evenly.
to prevent leaks. If the gasket is too long or too short, the
lid might not close properly or leaks could occur.