Dismantle the machine oil ruler, rub up it with
clean duster cloth, and stick it into the oil-
filling mouth to check the oil level. Pay
attention not to drop the ruler into it.
If the machine oil level is below the bottom of
the machine oil ruler, fill the recommended
machine oil into the fuel-filling mouth.
If the engine runs when oil is in shortage, it can be seriously damaged.
1 – Oil fiiling lid (Fig. H)
11.1.2 Check the fuel level
Please use fuel for cars. (It's better to use
no lead fuel or having low content of lead,
in order to reduce the accumulation of
charcoal in the burning room.)
If the fuel level is too low, please add fuel
into the fuel tank until it reaches the required level.
The fuel is very easy to burn or explode
under specific conditions.
Please fill the generator in a draught, and
turn off the engine before filing. It is
strictly forbidden to smoke close to the fuel-filling and fuel-storing parts of the generator.
The fuel must not be spilled out of the fuel tank (the fuel-filling mouth should not have any
fuel). Screw down the fuel-filling lid after filling the fuel.
Be careful not to let the fuel spill out when filling the generator. The fuel overflowed or mist
may take fire. Once there is some oil spilling out, make sure that the oil-spilled area is dried
before starting the engine.
Avoid exposing your skin to the fuel in a long time or repeatedly. Do not let children have
contact with it.
11.1.3 Intelligent fuel-saving valve
Function:
When the engine is disconnected from the
electrical equipment, the velocity of the
generator will slow down automatically.
When the equipment is connected, the
electric charge will make the generator
return to a proper rotate speed. This
installation is used to reduce the fuel
consumption during the running process.
On the position OFF:
It means the intelligent fuel-saving system is
closed, and the rotate speed of the
generator is kept on a level higher than the
standard rotate speed.
ZIPPER MASCHINEN GmbH
ZI-STE2000IV
2 – Oil filing mouth (Fig. H)
www.Zipper-Maschinen.at
I M P O R T A N T
The oil alarming system will turn off the
engine before the oil level descends to
the security line. But to avoid the
inconvenience caused by unexpected
machine halt, we advise you to check
the oil level regularly.
3 – Upper oil level (Fig. H)
I M P O R T A N T
Prevent filth, dust, or water
entering the fuel tank.
Screw down the fuel-filling lid after
filling the fuel.
Do never use the mixture of machine
oil and fuel or uncleaned fuel.
When the electrical equipment
needs disconnecting from the
electric power, the intelligent fuel-
saving system can not run
effectively.
When the generator is connected with a
high electric charge, turn off the
intelligent fuel-saving valve to minimize
the change of middle pressure.
When using the DC output, please
turn off the intelligent fuel-saving
valve. (Fig. D)
OPERATION
31