3.5 Determine The Motor Connection
1. Connect one end of the test leads to the Phase & Motor
Rotation Meter, make sure the L1, L2 and L3 test leads are
connected to the corresponding jack.
2. Connect the alligator clips to the other end of the test leads.
3. Connect the alligator clips to the motor connections, L1 to U,
L2 to V, L3 to W.
4. PRESS the ON/OFF Button, the green ON indicator shows
that the instrument is ready for testing.
5. Turn the motor shaft half a revolution towards the right.
NOTE: The bottom of the Phase & Motor Rotation
Meter should be oriented towards the drive shaft. See
the Orientation Symbol on the Phase & Motor Rotation
Meter.
NOTE: Either the Clockwise or Counterclockwise Rotary
indicator illuminates showing the type of rotary field
direction present.
3.6 Magnetic Field Detection
ƒ To detect a magnetic field, place the Phase & Motor Rotation
Meter to a solenoid valve.
ƒ A magnetic field is present if either the Clockwise or the
Counterclockwise.