DESCRIPTION OF THE PRODUCT
4

OPERATION MODES

Semi-automatic mode
Opening
The opening process is initiated by activating the
control device (wall button, remote control or button |+
of the actuator control panel).
If a control device is activated during opening, the
door comes to a halt. If the following are then
activated:
• the button |+ of the control panel, the door
continues to open.
• the remote control or wall button, the door
closes.

Automatic mode

Opening
The opening process is initiated by activating the
control device (wall button, remote control or button |+
of the actuator control panel).
If the remote control or wall button is activated
during opening, no action is carried out. If |+ or |-
is pressed, the door comes to a halt.
Standby
The door remains open during the programmed time.
If the remote control or wall button is activated
during standby time, no action is carried out.
If the button |- is pressed during standby, the door
closes.
If the photocell is activated during standby, standby
time continues to elapse.
50
Installation Manual
Standby
The door remains open indefinitely until the control
device is operated (wall button, remote control or the
button |- of the control panel).
Closing
The opening process is initiated by activating the
control device (wall button, remote control or button |-
of the control panel).
If the button |+ or |- is activated during closing, the
door comes to a halt and remains on standby.
If the remote control or wall button is activated
during closing, the door inverts operation direction
and opens completely.
Closing
At the end of standby time, the indicator light flashes
for a few seconds and the closing operation then starts
(provided the photocell is not activated).
If the photocell is activated at the end of standby time,
the door does not close until the photocell is disabled.
If the |+ or |- control panel button is activated
during closing, the door comes to a halt and remains
on standby (closing once standby time has passed).
If the remote control or wall button is activated
during closing, the door inverts operation direction
and opens completely.