Actuator Installation - Erreka FENIX Manual Del Instalador

Accionador de techo
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

INSTALLATION
• The installation must be able to support the
power consumed by all the automatic
operation devices.
• The installation must be earthed.
• The electrical installation must comply with
low voltage regulations.
4

ACTUATOR INSTALLATION

Assembly positions and levels (sectional door)
1
Front support
2
Door anchoring
3
Overhead strips
Level A: the track (4) should remain 10 cm
above the highest point of the door (see detail
A ).
Level B: in accordance with the chosen track
(track ref. AFE01: 3m; track ref. AFE02: 4m).
Fig. 4
Assembly positions and levels
54
Installation Manual
• The installation elements must be properly
secured and in a good state of conservation.
• The current connection point must be high
enough to be out of the reach of children.
If the electrical installation does not comply
with the foregoing requirements, repair before
installing the automatic operation device.
4
Actuator track
5
Door tracks
6
Door
Level C: height of the unlocking cable (7):
approximately 1.8 m over the ground (lengthen
or shorten as appropriate).
O
The track (4) must be horizontal.
7
Unlocking cable
8
Carriage
9
Actuator

Publicidad

Tabla de contenido
loading

Tabla de contenido