Tighten the chain
3
4
2
Lubricate the track
Connect the actuator to the rest of the installation elements
A.T. Wall key or button
S
Safety device (photocell)
BAT Emergency battery (2x12V)
AUX Power supply for peripherals (24Vdc)
1 Tighten the nut (4) as far as possible, and then
loosen it slightly until the sleeve (2) can be turned by
hand.
2 Check that the chain is taut by carrying out several
opening and closing cycles of the door.
Excessive tautness may lead to breakage or
premature deterioration of the pieces.
If the chain is loose, a noise will be heard when
closing the door.
1 Apply lubricant grease throughout the length of the
carriage-track contact area.
Complete the installation in line with the low
voltage regulations and applicable rules.
Check the manufacturer's instructions for all
the elements installed.
1 Connect the wall key or button terminals and the
KEY-GND terminals of the actuator.
2 Connect the emergency battery to the BAT-GND
terminals of the actuator.
O
Respect the polarity.
3 Connect the NC contacts of the photocell and the IN-
GND terminals of the actuator.
If photocells are not used, it is necessary to make
a bridge between the corresponding terminals of
the actuator.
The terminals +24 and GND can be used to feed
the photocell.
INSTALLATION
59
FENIX Overhead Actuator