Operating instructions and warnings
WARNING All the other adjustment/setting operations beyond
the adjustment of the oil flow are made by the manufacturer.
Tampering with these settings may cause malfunction and/or
situations of risk to people, animals and property. Refrain from
performing any operations not authorised by DEA System.
4.5.6 Maintenance and repair
Good preventive maintenance and regular inspection ensure
long working life (see also "Warranty"). Consult the "TROUBLE-
SHOOTING" table (see page 9) whenever anomalies are obser-
ved in order to find the solution to the problem and contact DEA
System directly whenever the solution required is not provided.
The inspection/maintenance operations to be routinely sche-
duled in the "complete automatism maintenance register" are:
INTERVENTION TYPE
cleaning of external surfaces
checking of screw tightening
checking of release
mechanism operation
WARNING All installation, maintenance, cleaning or repair
operations on any part of the system must be performed
exclusively by qualified personnel with the power supply
disconnected working in strict compliance with the electrical
standards and regulations in force in the nation of installation.
WARNING The use of spare parts not indicated by DEA Sy-
stem and/or incorrect re-assembly can create risk to people,
animals and property and also damage the product. For this
reason, always use only the parts indicated by DEA System
and scrupulously follow all assembly instructions.
4.6
Training
After installation and setting, the correct operation of the
complete automatism must be carefully illustrated to the final
user.
The LIVI 400 gate operator requires careful instruction on
the release mechanism (see "Enclosures") in particular and the
respective maintenance schedule (see Point 4.5.6.).
WARNING Awareness of the operation of the LIVI 400 key-
release mechanism (see F9 Page 32) is essential for all users
of the automatism because the failure to use the device qui-
ckly during emergencies can jeopardise people, animals and
property. Enclosure I to these instructions, which the installer
is required to deliver to the final user, illustrates operation and
can be detached.
4.7
Inappropriate use
Chapter "4.4 Appropriate conditions of use" describes the
conditions for which the product has been designed and tested.
The product must never be used for other purposes.
10
WARNING The use of the product under unusual conditions
not foreseen by the manufacturer can create situations of dan-
ger, and for this reason all the conditions prescribed in these
instructions must be respected.
WARNING Under no circumstances must the product be
used in explosive atmospheres or surroundings that may prove
corrosive and damage parts of the product.
5 SPARE PARTS LIST
The list of spare parts that can be ordered (Pages 28, 29 and
33) is a detailed list that accompanies the exploded view of the
product and must be used to order spare parts.
The following data must always be provided when ordering
spare parts:
• the code of the product (seen on the product label; see F5,
Page 31),
L I V I 4 0 0
• the part's position number in the exploded view,
• if available, the product's purchase date may be useful in
some cases.
This chapter illustrates the typical installation of a com-
plete automatism for the purpose of informing and assisting
the installer in the selection of the various parts to be used in
compliance with Machinery Directive (98/37/CE) and European
Safety Standards (EN 12453 - EN 12445) for gate installation.
The data provided in this chapter are neither complete nor
exhaustive, and DEA System declines all liability for any errors,
omissions or inaccuracies that may occur.
PERIODICITY
6.1
6 months
6 months
The risk of getting crushed between the gate and the fence
or wall and/or other fixed parts is among the most serious risks
6 months
to be considered when automating a sliding gate is. An appro-
priate type of operating control board must be used according
to the gate type and use against such risk, as provided for by the
quoted regulations (see "OPERATING CONTROL" table).
6.2
The risk of crushing can also arise in the area between the
gate being opened and the wall or other construction behind
it. F10 on Page 32 provides the measurements that must be
respected whenever measures are not taken to limit the impact
force or whenever presence detection systems are not used.
6.3
Install a pair of photocells on one or the other side of the
gate or on both in order to avoid the risk of impact with the gate
in the closing area. (recommended height: 500 mm) in order to
detect the presence of the test parallelepiped (height: 700 mm)
positioned as shown in F11 on Page 32.
Note. The presence detection test sample is a parallelepiped
with 3 sides with light-coloured reflecting surfaces and 3 sides
with dark-coloured, opaque surfaces.
Make sure there is no conflict when the photocells are instal-
led on both sides. The system working on the gate side where the
test sample is positioned must detect all test objects.
6 COMPLETE CLOSING ASSEMBLY
Minimum level of protection provided by the
safety edge
Crushing in the opening area
Impact in the opening/closing area