7) Interrupting a cycle.
The machine immediately stops the cycle
and the chamber is decompressed when
the StOP button is pressed at any time.
The lid is opened automatically. The ma-
chine returns to the set program.
8) End of cycle.
The lid is opened automatically. Remove
the packed product, paying attention not
to touch the sealing bar, which could still
be hot.
8.6 PUMP OIL dEhUMIdIFICaTION CyCLE
Read Chapter 6.4 carefully
The cycle lasts 20 minutes and must be run weekly or more often in accordance with machine use.
1) Program the parameters.
Turn the machine on using the main switch
OUT" program using the UP/dOWN keys
Select the "h
2
2) Cycle start-up.
Lower the lid using both hands by pres-
sing both corners of the lid.
The cycle starts automatically.
3) End of cycle.
At the end of the cycle, the machine
returns to idle mode. It is ready for a nor-
mal operation cycle according to the set
program.
4) Stopping the cycle in advance.
The dehumidification cycle can be inter-
rupted at any time by pressing the StOP
button.