Corghi LaserLine EM 9580 Plus Manual De Uso página 51

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 175
CAUTION
to facilitate the access of the cable in the slots
on the metal tube, it is advisable to remove the
tube from the rotation pin by unscrewing the
M12 screw present.
- fix the ultrasonic sensor support to the guard
pipe using the supplied screws (Fig.9a);
- connect the sensor cable to the connector on
the side of the casing (A, fig.9b)
- Adjust the length of the ultrasonic sensor cable
near the connector (A, fig. 9b) with closed pro-
tection, to avoid deformation of the connector
itself during handling of the wheel guard.
- Then lock the cable through the supplied strap
(A, fig.9). Any excess cable in the object will be
inserted and locked (by means of the bases
already present) inside the sensor support.
To access inside the sensor holder, remove
the plastic cover by unscrewing the four fixing
screws (Fig. 9c).
EM 9580 Plus - EM 9580 C Plus - Operator's manual
- check and eventually act on the ultrasonic sensor
holder until the required distance between the
9a
calibration template and the support (Fig. 9d)
is reached, proceeding as follows:
1. Fix the ultrasonic sensor calibration template
in the kit using the centering accessories on
the shaft of the oscillating unit;
2. Lower the wheel guard;
9b
CAUTION
Lowering the wheel guard enables the launch of
the swinging group with the blocked template !!!
3. Align the ultrasonic sensor calibration template
to the ultrasonic sensor support and test its
distance using a meter, ie:
to. 285mm (tolerance +/- 5mm)
IMPORTANT: once the ultrasonic sensor is
assembled, calibrate the sensor as described
in the paragraph "Calibration of the ultrasonic
width sensor".
9c
UK
9d
51

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Laserline em 9580 c plus

Tabla de contenido