5. spin again;
6. At the end of the spin, change the position
of the calibration weight on the swinging unit
bell as indicated in figure 28;
7. spin a third time;
At the end of the fourth calibration spin, the ma-
chine will automatically perform two subsequent
spins at different wheel rotational speeds that
are lower than the previous spins.
If the calibration has been successful, a permis-
sion acoustic signal goes off at the end of the
spin; otherwise, the E 2 message is temporarily
displayed.
Notes:
-
Once the procedure is finished, remove the
calibration weight.
-
Press the
calibration procedure at any time.
-
This calibration is valid for any kind of wheel.
Calibration of the ultrasonic
width sensor (if installed)
- select the ultrasonic width sensor calibration
icon
located in the configuration pro-
grammes;
- fix the calibration template in correspond-
ence of the threaded hole located in the shaft
assembly bell using the M8 screw (A, Fig.29)
supplied with the ultrasonic sensor;
80
28
button to interrupt the
EM 9580 Plus - EM 9580 C Plus - Operator's manual
- use the locking device with a wheel spacer (ma-
chine version with automatic locking system)
or a cone and the wheel fixing nut to bring the
template in contact with the shaft assembly
bell (fig.29);
- press the Kis knob or the ENTER button to
confirm the securing of the template;
- slowly turn the template towards the operator
to automatically enable the clamping brake
(fig.30);
- slowly lower the wheel guard (fig. 31), the ma-
chine will automatically calibrate the sensor.
If the calibration has been performed successfully,
a consent message is displayed.
On the contrary, the display of the message A20
indicates that:
- the position of the calibration template during
the calibration phase is not correct. Therefore,
29
30