A 25
Programme not available on this model.
A 26
Programme available only after selecting one
of the following programmes: ALU 1P / ALU 2P /
Motorcycle Dynamic / Motorcycle Alu.
A 31
Optimisation procedure (OPT) already launched
by another user.
A 51
Incorrect wheel clamping (only with the automatic
wheel clamping system).
Repeat the locking operation.
A 52
hub mounting/demounting procedure started
automatic wheel clamping system.
After 30 seconds, the procedure ends auto-
matically.
A Stp
Wheel stop during the spin phase.
A Cr
Spin performed with the guard raised.
Lower the guard to perform the wheel spin.
– E – Error Messages
E 1
Sensitivity calibration missing. Perform the
sensitivity calibration procedure.
E 2
Error condition on sensitivity calibration.
the sensitivity calibration, paying attention to the
first spin, which must be performed with the wheel
like the subsequent spins.
Take particular care NOT to knock the machine
during calibration.
E 3 I/E 2/3
Error condition at the end of sensitivity calibration.
Repeat the calibration, if the message persists
perform the following checks:
• Correct sensitivity calibration procedure;
• Correct fastening and position of the calibration
weight;
• Mechanical and geometric condition of the ca-
libration weight;
• Geometry of the wheel used.
E 4
a) Error condition on sensor calibration.
Perform the sensor calibration procedure.
b) External sensor missing.
error can be disabled by performing the
following procedure:
-
Select ultrasonic width sensor calibration
82
Repeat
Visualisation of this
EM 9580 Plus - EM 9580 C Plus - Operator's manual
and press the Kis knob or the
ENTER button.
E 6
Error condition when executing optimisation
programme.
Repeat the procedure from the beginning.
E 12
External sensor not present or
of this error can be disabled by performing the
following procedure:
-
Select ultrasonic width sensor calibration
and press the Kis knob or the
ENTER button.
E 27
Excessive braking time. If the problem persists,
call in the technical support centre.
E 28
Encoder counting error. If the error occurs fre-
quently, call in the technical support centre.
E 30
Spin device failure. Switch off the machine and
call in the technical support centre.
E 32
The wheel balancer was jolted during the reading
phase. Repeat the spin.
E 50
Automatic wheel clamping system fault.
Restart the wheel balancer.
If the error persists, request servicing.
E F0
Error in reading the 0 notch.
CCC CCC
Unbalance values greater than 999 grams.
CHECK FOR CORRECT
FUNCTIONING OF
BALANCING ACCESSORIES
Checking balancing accessories allows the oper-
ator to make sure that wear has not altered the
mechanical specifications of flanges, cones, etc.
beyond the specified limits.
A perfectly balanced wheel, which has been
disassembled and reassembled in a different
position, should not show an unbalance value
faulty.