Corghi LaserLine EM 9580 Plus Manual De Uso página 66

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 175
- Keep the arm in position and wait for the
acoustic confirmation signal.
IMPORTANT
The geometric data for real balancing plans
for the application of adhesive weights can be
detected by the laser line on the automatic
detector lever (if present).
To enable this line, it is necessary to press the
button on the lever (A, Fig.21a).
The laser line remains visible within the rim for
10 seconds then, if necessary, press the lever
button again.
- Return the measuring arm to the rest position.
- Perform a spin.
- At the end of the spin, if you want to change the
balancing programme set automatically by the
machine (FSP), select the balancing programme
icon
and press the Kis knob or the
ENTER button until the required programme
is displayed.
Balancing weight application
- Select the plane where the first balancing weight
is to be applied.
- Turn the wheel until the central element of the
corresponding position indicator lights up.
If the weight to be applied is of the traditional
clip type (inner side in ALU 2P), apply it to the 12
o'clock position.
If instead the weight to apply is
adhesive and the CLIP mode was selected (see
the " Selection of adhesive weight application
66
position"):
- Centre it inside the cavity of the weight-holder
terminal of the measuring arm (fig. 22 a,b), with
the backing paper of the adhesive strip facing
up. Remove the protection (fig. 22 c) and turn
the terminal so that the adhesive faces the inner
surface of the rim.
- Move the sensor until the two reference lines
(green in colour) coincide in the relevant win-
dows on the screen.
- Turn the end of the measuring arm until the
weight adhesive strip is in line with the rim
surface.
- Press the button (fig. 22 d) to eject the weight
and make it stick to the rim.
- Return the measuring arm to the rest position
(fig. 22 e).
a
21a
- Repeat the operations to apply the second
balancing weight.
- Perform a test wheel spin to check the balancing
accuracy.
- If the weight to apply is adhesive and H12 mode
was selected, apply it on both the planes in the
position corresponding to 12 o'clock.
- If the weight to apply is adhesive and the
LASER mode was selected, apply the weight in
correspondence of the laser line in the position
in which the respective plane was acquired.
The rim surface must be perfectly clean to make
the weight stick efficiently to the rim. If neces-
sary, clean the surface using suitable cleansing
products.
NOTE: on the wheel balancers for the German
market, the weight must be applied as follows:
apply the weight manually by positioning it so
that its centre line is 15mm back from the contact
point of the measuring head with the rim.
EM 9580 Plus - EM 9580 C Plus - Operator's manual
b
c
d
e
22

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Laserline em 9580 c plus

Tabla de contenido