ELECTRICAL CONNECTIONS
Use 230 V 50 Hz alternate voltage equipped with a earthing conductor to supply your machine. Ensure that the
power supply corresponds to this voltage, that it is protected by a differential and magnetothermal switch, and
that the earthing system is efficient. If your machine does not work when connected to a socket, check carefully
the power supply features.
Use an extension cable in order to connect the machine to the power supply.
EARTHING INSTRUCTIONS
If the tool does not work properly or in case of short-circuit, the earthing system provides the current with a less
resistance path and reduces the risk of electric shock. This tool has a plug to which a supply or extension cable
must be connected, which in turn must be connected to a socket correctly installed and earthed, in conformity
with local standards and regulations. Be sure that your earthing system is in good conditions and that your plug
is protected by a differential and magnetothermal switch.
If the earthing conductor is not connected correctly the risk of electric shock can occur. The conductor which
has the green insulating jacket (with or without a yellow line) is the earthing conductor.
Consult a qualified electrician or a person in charge of the maintenance if you have not understood or you have
some doubts on the earthing instructions.
If the supply cable is damaged it must be changed by qualified people. Do not switch on the machine if the
supply cable is damaged.
EXTENSION LEADS
Only use three conductors extension leads, with a plug with two plugs and a earthing contact and sockets with
two holes and a earth corresponding to the plug of the tool. When using an electric tool at a remarkable distance
from the power supply, use an extension lead with sufficient dimensions to transport the current which the tool
needs. If the extension lead has not the sufficient dimensions a voltage drop can occur, thus causing an
overheating and a voltage loss. You can only use extension leads which are in compliance with CE standards.
Extension lead length: .......................................................................................................................... up to 15 m
Cable dimensions: .............................................................................................................................. 3 x 2,5 mm²
Before using any kind of extension lead, check that it has not bare wires and that the insulation is not cut or
worn. Repair and change immediately it if it is damaged or worn.
WARNING:
EXTENSION LEADS MUST BE ARRANGED AWAY FROM THE WORKING AREA IN
ORDER THAT THEY NOT GET IN TOUCH WITH THE WORKPIECES, THE TOOL OR
OTHER PARTS OF THE MACHINE, THUS CREATING POSSIBLE RISKS.
WARNING:
KEEP THE TOOLS AND THE EQUIPMENT AT A SAFE DISTANCE FROM CHILDREN
EN
ELECTRICAL CONNECTIONS
25