Technical Data / Maintenance; Cooling Unit; Power Source - Migatronic PI 250 AC/DC HP Manual De Instrucciones

Ocultar thumbs Ver también para PI 250 AC/DC HP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 75
TECHNICAL DATA

Power source:

Mains voltage (50Hz-60Hz)
Fuse
Fuse with PFC
Mains current, effective
Mains current, effective with PFC
Power, (100%)
Power, (100%) with PFC
Power, max
Power, max. with PFC
Open circuit power
Efficiency
Power factor
Permitted load:
Duty cycle 40° TIG 100%
Duty cycle 40° TIG 60%
Duty cycle 40° TIG 40%
Duty cycle 40° TIG 30%
Duty cycle 20° TIG 100%
Duty cycle 20° TIG 60%
Open circuit voltage
Current range
1
Application class
2
Protection class (IEC 529)
Standards
Dimensions (hxwxl) (mm)
Weight
Water cooling:
Cooling capacity
Tank capacity
Standards
Dimensions (hxwxl) (mm)
Weight
Function:
Arc-power
Hot-start
Anti-freeze
Start AMP
Stop AMP
Slope up
Slope down
Gas pre-flow
Gas post-flow
Spot welding time
Pulse time
Pause time
Base Amp
Second current (Bilevel)
AC-balance
AC-balance, Ampere
AC-frequency*
TIG-ignition
Triggerfunction
* In electrode the frequency is 50 Hz
S
1
The machine meets the standards which are demanded of machines
working in areas where there is an increased risk of electric shock
2
Equipment marked IP23 is designed for indoor and outdoor
applications
PI 200 AC/DC
PI 250 AC/DC
1 x 230 V ±15%
3x400 V ±15%
-
10 A
16 A
-
-
7.3 A
18.6 A
-
-
5.0 kVA
4.3 kVA
-
7.1 kVA
6.0 kVA
-
35 W
35 W
0.80
0.81
0.93
0.94
140 A
150 A
170 A
180 A
200 A
-
-
250 A
160 A
170 A
200 A
200 A
95 V
95 V
5-200 A
5-250 A
S
S
IP 23
IP 23
EN/IEC60974-1
EN/IEC60974-3
EN/IEC60974-10 (Class A)
360x220x520
360x220x520
24 kg
25 kg
PI 200/250 AC/DC
900 W
2 litres
EN/IEC60974-2
270x220x520
15 kg (incl. 2 l water)
Process
PI 200/250 AC/DC
Electrode
0-100 %
Electrode
0-100 %
TIG/Electrode
Always on
TIG
1-200 %
TIG
1-90 %
TIG
0-20 secs
TIG
0-20 secs
TIG
0-10 secs
TIG
0-20 secs
TIG
0-180 secs
TIG/MMA
0.01-10 secs
TIG/MMA
0.01-10 secs
TIG/MMA
10-90 %
TIG
10-200%
(only TIG AC)
20-80 %
(only TIG AC)
30-170 %
(only TIG AC)
25-150 HZ
TIG
HF / LIFTIG
TIG
2/4-stroke
MAINTENANCE
The machine requires periodical maintenance and
cleaning in order to avoid malfunction and cancellation
of the guarantee.
WARNING !
Only trained and qualified staff members can carry
out maintenance and cleaning. The machine must
be disconnected from the mains supply (pull out
the mains plug!). Thereafter, wait around 5
minutes before maintenance and repairing, as all
capacitors need to be discharged due to risk of
shock.

Cooling unit

Liquid level and frost protection must be checked
-
and cooling liquid refilled as required.
Drain the cooling liquid out of the cooling module
-
and welding hoses. Remove dirt and flush with
pure water in the tank and cooling hoses. Fill up
with new cooling liquid. The machine is delivered
with a cooling liquid of type propan-2-ol in the ratio
23% propan-2-ol and 77% demineralized water,
which provides an anti-freeze solution up to –9°C.
(See article number in the spare parts list).
Power source
Clean the fan blades and the components in the
-
cooling pipe with clean, dry, compressed air as
required.
-
A trained and qualified staff member must carry out
inspection and cleaning at least once a year.
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pi 200 ac/dc hpPi 200 dc hpPi 250 dc hp

Tabla de contenido