PRINCIPLE OF OPERATION
The stoves heat the air using wood pellets as fuel, with electro-
nically controlled combustion. Hereunder is the explanation of
its functions (the letters refer to gure 1).
The fuel (pellets) is transferred from the storage hopper (A)
to the combustion chamber (D) by means of a feed screw (B),
which is driven by a gear motor (C).
The pellets are ignited by the air that is heated by an electrical
resistance (E) and drawn into the combustion chamber by a
smoke extractor (F).
The fumes produced during the combustion process are
extracted from the hearth by the same centrifugal fan (F) and
expelled through the outlet (G) located on the lower part at the
back of the stove.
The stoves allow for hot air channelling to to convey the
air to heat adjacent rooms.
Two male pipes of a Ø 10 cm for hot air channelling connec-
tion are found on the back part.
To channel the hot air in one or two adjoining rooms, the stove
is equipped with two pipes on the back, to which special alumi-
nium pipes must be connected.
KIT 11 and KIT 11 BIS optional are available to facilitate air
distribution (see page 34-35-36).
Fuel quantity, smoke extraction and combustion air supply
are all controlled by an electronic control board, which is
equipped with Leonardo
®
software to achieve high combustion
ef ciency and low emissions.
The synoptic panel (M) is installed on the top, through
which all phases of operation can be displayed and controlled.
The main functions can also be controlled by remote control.
A serial port is found at the back of the stove (optional
cable: code 640560) to be connected to devices that allow
remote ignition (e.g. remote telephone, local thermostat).
The stoves have an internal structure that is made entirely
of cast iron.
D
F
g. 1
M
A
B
E
C
G
- 26
-
SAFETY INFORMATION
The stove is designed to heat, through automatic pellet com-
bustion in the hearth, the room where it is installed, both by
radiation and the air that comes out of the front grille.
• The appliance is not designed to be used by people, including
children, with reduced physical, sensorial or mental abilities.
Children must be supervised to ensure they do not play with
the appliance.
• The only risks that may derive from using the stove pertain
to non-compliance with installation instructions, direct contact
with live electrical parts (internal), contact with the re or hot
parts (glass, pipes, hot air output), when extraneous substances
or non-recommended fuel are introduced, or due to incorrect
maintenance.
• Only use certi ed, high quality, 6mm diameter wooden pellets
for fuel.
• Should components fail, the stoves are equipped with safety
devices that guarantee automatic shutdown. These are activated
without any intervention required.
• In order to function correctly, the stove must be installed in
accordance with the instructions given herein and the door
must not be opened during operation: combustion is fully
automatic and requires no intervention.
• Under no circumstances should any foreign substances be
entered into the hearth or hopper.
• Do not use ammable products to clean the smoke channel
(the ue section connecting the stove smoke outlet to the
chimney ue).
• The hearth and hopper parts must only be cleaned when
COLD.
• The glass can be cleaned when COLD with a suitable product
(e.g. GlassKamin Edilkamin) and a cloth.
• Do not clean when hot.
• Make sure the stove is installed and ignited the rst time
by Edilkamin-quali ed CAT personnel (technical assistan-
ce centre) in accordance with the instructions provided here
within; this is an essential requirement for the validation of the
guarantee.
• When the stove is in operation, the exhaust pipes and door
become very hot (do not touch without wearing the thermal
glove).
• Do not place anything, which is not heat resistant near the
stove.
• NEVER use liquid fuel to ignite the stove or rekindle the embers.
• Do not obstruct the ventilation apertures in the room where
the stove is installed, nor the air inlets of the stove itself.
• Do not wet the stove and do not go near electrical parts
with wet hands.
• Do not use reducers on the smoke exhaust pipes.
• The stove must be installed in a room that is suitable for
re prevention and equipped with all that is required (power
and air supply and outlets) for the stove to function correctly
and safely.
• Should ignition fail, DO NOT re-ignite until you have
emptied the combustion chamber.
•ATTENTION: THE PELLET EMPTIED FROM THE
COMBUSTION CHAMBER MUST NOT BE DEPOSI-
TED INSIDE THE HOPPER.TED INSIDE THE HOPPER.