Application - mundoclima AEROTHERM MAM-V9 Serie Manual De Usuario E Instalacion

Monobloc
Ocultar thumbs Ver también para AEROTHERM MAM-V9 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Coding
Assembly unit
1
Outdoor unit
1.1
Manometer
Pressure relief valve
1.2
Expansion vessel
1.3
Plate heat exchanger
1.4
1.5
Backup heater(Customized model)
Air purge valve
1.6
1.7
Flow switch
P_i: Circulate pump in the unit
1.8
<VKDSH ¿OWHU
2
3
6WRS YDOYH ¿HOG VXSSO\
4
Wired controller
'UDLQ YDOYH ¿HOG VXSSO\
6
The volume of balance tank(8) should be greater than 40L(for 5~9kW unit, greater than 20L) The drain valve (6)
should be installed at the lowest positon of the system. An independent backup heater can be selected and installed
in the door.
As the temperature sensor attached in the user interface is used to detect the room temperature, the user interface
(4) should be placed in the room where floor heating loops and fan coil units is installed and away from the heating
source. Correct configuration should be applied in the user interface (refer to 10.7 field settings/TEMP. TYPE
SETTING). The first setpoint is water temperature which can be set on the main page of user interface, the second
setpoint is calculated from climate related curves, the target outlet water temperature is the higher one of these two
setpoints. The unit will turn off when the room temperature reaches the target temperature.
Pump operation and space heating
The pump (1.8) and (10) will operate when there is request for heating from A and/or B. Pump (23.1) will operate when the room
temperature of zone B is lower than the set point which set in the user interface. The outdoor unit will start operating to achieve
the target water flow temperature.

8.8 Application 8

Space heating application and domestic hot water heating with a solar energy kit connected to the system; space heating is
provided by heat pump, domestic hot water heating is provided by heat pump and solar energy kit.
26
1
1.6
1.7
1.5
1.8
1.3
1.4 1.2
Coding
8.1
8.2
10
11
17
19
23
23.1
FHL 1...n
FCU 1...n
NOTE
27
18
1.1
2
3
6
7
8
113
Assembly unit
)LOO YDOYH ¿HOG VXSSO\
7
%DODQFH WDQN ¿HOG VXSSO\
8
Air purge valve
Drain valve
([SDQVLRQ YHVVHO ¿HOG VXSSO\
9
3BR 2XWVLGH FLUFXODWLRQ SXPS ¿HOG VXSSO\
&ROOHFWRU ¿HOG VXSSO\
%\SDVV YDOYH ¿HOG VXSSO\
69ZD\ YDOYH ¿HOG VXSSO\
0L[LQJ VWDWLRQ ¿HOG VXSSO\
P_c: mixing pump
)ORRU KHDWLQJ ORRS ¿HOG VXSSO\
)DQ FRLO XQLWV ¿HOG VXSSO\
4
12.1
12.1
9
8.1
10
8.2
FHL1
12
14
13
15
12.3
16
12.2
11
17
----
----
FHL2
FHLn

Publicidad