Overview Of The Unit; Disassembling The Unit - mundoclima AEROTHERM MAM-V9 Serie Manual De Usuario E Instalacion

Monobloc
Ocultar thumbs Ver también para AEROTHERM MAM-V9 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Coding
Assembly unit
1
Outdoor unit
1.1
Manometer
Pressure relief valve
1.2
Expansion vessel
1.3
Plate heat exchanger
1.4
1.5
Backup heater(Customized model)
Air purge valve
1.6
1.7
Flow switch
P_i: Circulate pump in the unit
1.8
<VKDSH ¿OWHU
2
3
6WRS YDOYH ¿HOG VXSSO\
4
Wired controller
'UDLQ YDOYH ¿HOG VXSSO\
6
7
)LOO YDOYH ¿HOG VXSSO\
%DODQFH WDQN ¿HOG VXSSO\
8
Air purge valve
8.1
8.2
Drain valve
The volume of balance tank(8) should be greater than 40L(for 5~9kW unit, greater than 20L) The drain valve (6) should
be installed at the lowest positon of the system. An independent backup heater can be selected and installed in the
door.
The pump (1.8) and (10) will operate when there is a request for heating floor heating loops. The outdoor unit will start operating
to achieve the target water flow temperature. The target water can be set in the wired controller.
If solar energy is set avaliable in the wired controller(refer to 10.7 Field settings/OTHER HEATING SOURCE), the heating of
domestic hot water can be done by either the solar energy kit or heat pump. when the solar energy kit turns on, signal will be
sent to the outdoor unit, then the pump (27) will operate, the heat pump will stop heating for domestic hot water during solar
energy kit operation .
Make sure to wiring the solar energy kit(26) and solar pump(27) correctly, refer to "9.6.6 Connection for other
components/For solar energy kit". User interface should be correctly configured, refer to "10.7 Field settings/OTHER
HEATING SOURCE".

9 OVERVIEW OF THE UNIT

9.1 Disassembling the unit

Door 1
To access to the compressor and
electrical parts and hydraulic
compartment
1
5/7/9kW
Coding
Assembly unit
([SDQVLRQ YHVVHO ¿HOG VXSSO\
9
3BR 2XWVLGH FLUFXODWLRQ SXPS ¿HOG VXSSO\
10
&ROOHFWRU ¿HOG VXSSO\
11
12
'RPHVWLF KRW ZDWHU WDQN ¿HOG VXSSO\
12.1
Air purge valve
Heat exchanger coil
12.2
Booster heater
12.3
T5: Temperature sensor
13
14
+RW ZDWHU WDS ¿HOG VXSSO\
3BG '+: SXPS ¿HOG VXSSO\
15
2QH ZD\ YDOYH ¿HOG VXSSO\
16
%\SDVV YDOYH ¿HOG VXSSO\
17
69 ZD\ YDOYH ¿HOG VXSSO\
18
)ORRU KHDWLQJ ORRS ¿HOG VXSSO\
FHL 1...n
6RODU HQHUJ\ NLW ¿HOG VXSSO\
26
3BV 6RODU SXPS ¿HOG VXSSO\
27
/
NOTE
NOTE
Door 1
To access to the compressor and
electrical parts.
Door 2
To access to the hydraulic
compartment and electrical parts.
1
12/14/16kW
114
/
2