mundoclima AEROTHERM MAM-V9 Serie Manual De Usuario E Instalacion página 121

Monobloc
Ocultar thumbs Ver también para AEROTHERM MAM-V9 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9.3.1 Main control board of hydraulic module
1
27
26
25
24
23
22
21
Coding
Input port for solar kits(CN5)
1
Output port for transformer(CN4)
2
Power supply port for the wired controller(CN36)
3
4
Port for remote switch(CN12)
3RUW IRU ÀRZ VZLWFK &1
5
Port for communication with the wired controller(CN14)
6
Port for communication with PCB B(CN19)
7
Port for temp.sensors(TW_out, TW_in, T1, T2,T2B )(CN6)
8
Port for temp.sensor(T5, domestic hot water tank temp.sensor)(CN13)
9
3RUW IRU WHPSVHQVRU 7% WKH ¿QDO RXWOHW WHPSVHQVRU &1
10
11
Digital display(DIS1)
Rotary dip switch(S3)
12
Dip switch(S1,S2)
13
Output port for deforst(CN34)
14
Port for anti-freeze eletric heating tape (internal)(CN40)
15
16
Port for anti-freeze eletric heating tape (internal)(CN41)
17
Output port for external heating source /Output for operation(CN25)
Port for anti-freeze eletric heating tape(HEAT) /solar energy pump(P_S)/remote alarm(ALARM)(CN27)
18
19
Port for external circulted pump P_o pipe pump(P_d)/mix pump(P_c)/2-way valve(SV2)(CN37)
20
Port for SV1(3-way valve) and SV3(CN24)
Port for internal pump(CN28)
21
22
Input port for transformer(CN20)
Feedback port for temperature switch(CN1)
23
24
Port for power supply(CN21)
25
Feedback port for external temp. switch(shorted in default)(CN2)
26
Control port for backup heater/booster heater(CN22)
Control port for room thermostat(CN3)
27
2
3
4
5
20
19
18
1-phase 5/7/9kW
1-phase 12/14/16kW
3-phase 12/14/16kW
Assembly unit
118
6
7
17
16
15
8
9
10
11
12
13
14

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido