Fault: Blockage in the downstream progressive system, continuation
Cause:
Metering device blocked
Fault: Differing lubricant amounts at the lubrication points
Cause:
Lubricant metering not correct
Setting of the pause time or operating time incorrect
Fault: Excessive or poor lubrication of the lubrication points
Cause:
Setting of the operating time or pause time incorrect
Tab. 1

Troubleshooting

Examples of model designations
Series
Number of outlets
Type of outlet tube fitting
Metering device crooked
Metering possibilities
A = 0.07 ccm
F = 0.6 ccm
B = 0.14 ccm
G = 0.8 ccm
C = 0.2 ccm
H = 1.0 ccm
D = 0.3 ccm
I = 1.4 ccm
E = 0.4 ccm
J = 1.8 ccm
Monitoring
Outlet tube fittings
Inlet tube fittings
Closed outlets
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Troubleshooting, continuation
Correction:
Correction:
Correction:

Selection Guide

Standard designation
SSVD
6
SSVD
14/13 -
SSVD
8
-
SSVD
14
- S -
Thoroughly rinse metering device with a manual pump.
If not possible, replace the metering device.
Remove all tube fittings.
IMPORTANT
The control pistons are fit into the metering
device bores. They must not be mixed up.
6001a02
Check the lubricant metering acc. to the lubrication chart.
Check the time setting.
Check the time setting at the control devices, printed circuit
boards or control units.
V1 -
K
ABCF
ACBGABC - N
- RV6 /
2.2A-20003-B07
Expanded designations
WEKV6
/ outlets 3, 6, 8, 10
Page 21 of 26