FLUSH TIMES/INTERVAL
INTERNAL FLUSH TIME
000s
000l
00s
External flush time
Interval pause
001m
NOTE
Volume controlled
Start via water meter
>VOLUME INTERVAL ▼▲ ME
0000l
▼▲
>
TYPE OF WATER METER
ME
1 LITRE/IMPULSE
2,5 Litres/Impulse
5 Litres/Impulse
10 Litres/Impulse
100 Litres/Impulse
*
500 Litres/Impulse
1000 Litres/Impulse
Enter the interval pause and the flush times
 In
, select
>BASIC PROGRAM
=>
=>
PROGRAM VALUES
=>
INTERVAL PAUSE
 Enter the "
INTERVAL PAUSE"
(1 minute is preset)
 Enter the "
INTERNAL FLUSH TIME"
(000 seconds (s) is preset)
 Enter the "
EXTERNAL FLUSH TIME"
(00 seconds (s) is preset)
 Press "ENTER" to complete all the entries
Duration of the analysis interval
 The analysis interval is the addition of the "AUX before
analysis", "Internal flush" and "External flush" times and
the measuring value dependent analysis duration (see
diagram on the left)
Minimum interval = 1 litre, maximum interval = 9999 litres. The
analysis is carried out once the programmed water quantity has been
measured. The line and the measuring chamber are flushed prior to
the analysis (observe the programmed flush times).
Selecting the volume control
 In
, select
>BASIC PROGRAM
=>
=>
PROGRAM VALUES
INTERVAL
 Press "ENTER" to confirm the selection
The menu on the left appears.
 Enter the respective flow rate in litres
 Press "ENTER" to confirm the entry
Selecting the type of water meter
 Select the
>BASIC PROGRAM
=>
=>
PROGRAM VALUES
METER
 Select the water meter constant (litre/impulse)
(100 litres/impulse " * " is factory set)
 Press "ENTER" to confirm the selection
Password protection and basic program
FLUSH TIMES/INTERVAL
in minutes (m)
in seconds (s)
in seconds (s)
=>
MODE OF OPERATION
VOLUME
menu
=>
WATER METER
TYPE OF WATER
Analysis
interval
Sequence of
times
25

Publicidad

Tabla de contenido
loading

Productos relacionados para Heyl Testomat 2000 PO4

Tabla de contenido