Figure 5. Example Of Bypass Installation - Nature2 Fusion soft Serie Manual De Instalación Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 14
Control Valve Installation Options
Install between the inlet
and discharge side of
Install on the inlet
bypass plumbing
side of the vessel
Nature
Flow
Figure 5.
Example of Bypass Installation
7.
Install a control valve in the return line between the fi rst and second tee or prior to the vessel inlet on the bypass
line to control the water fl ow through the bypass.
8.
Hand tighten all unions, sensors, and collars.
Be careful not to get fi nger caught between inlet union and plug when tightening as this may cause an injury.
9.
Fully open any closed valves, including the control valve, and start the pump diverting water through the new
bypass.
10. Check the vessel and system for leaks.
11. Adjust control valve so that fl ow rate through the vessel is between a minimum of 30 gpm (114 lpm) and a
maximum of 120 gpm (455 lpm).
Nature
Fusion Soft Installation and Operation Manual
Heater
Flow/Temperature/
Salinity Sensor
2
Fusion Soft
Flow
Flow/Temperature/
Salinity Sensor
Optional ChemLink or
other ORP Control
Pool Return
CAUTION
FUSIONM
or
APUREM
or
PureLink
TM
or
Existing AquaPure
®
Power Pac
k
Pump
Filter
Pool Intake
Spa Intake
Spa Return