3.11 Connecting the Nature
ATTENTION INSTALLER: If the fl ow/temp/salinity sensor is not installed properly, it may allow the vessel to
operate without water fl ow. This would cause a buildup of fl ammable gases resulting in FIRE or EXPLOSION.
•
Mount as shown in Figure 10. This will result in the most reliable operation.
•
IMPORTANT! Anytime the fl ow/temp/salinity sensor is connected or disconnected and reconnected, the AC
power to the unit must be turned off and back on (Cycle Power). If power is not cycled, unreliable operation of
the fl ow/temp/salinity sensor will result.
1.
Be sure pool pump is turned off.
2.
Install the fl ow/temp/salinity sensor into the vessel (see Figure 10).
3.
Install the strain relief provided with the vessel kit into the low voltage knock out at the power pack. Feed the
connector end of the fl ow/temp/salinity sensor cable through the DC cord strain relief fi tting. Be certain the
connector is clean and dry, then plug the cable into the connector on the power center printed circuit board as
shown in Figures 11, 12 and 13. (Do not pull fl ow/temp/salinity sensor cable too tight, allow some slack).
4.
Plug the DC cord into the cell stud terminals protruding from the cell top at the Nature
DC cord can be plugged into the cell in either direction.
5.
Connect the DC cord to the power center. Feed the DC cord through the same strain relief fi tting as the fl ow/
temp/salinity sensor at the power pack. Plug the DC cord into the two (2) spade connectors of the wiring harness
located in the low voltage raceway of the control/power center, see Figures 11, 12 and 13. This wiring harness
establishes the connection between the cell and the power interface board.
To avoid risk of damage to the equipment and possible injury, it is important to make sure the DC cable connector
is fully seated on the cell electrolytic stud terminals.
Figure 10.
Vessel Installation and Flow/Temp/Salinity Sensor
Nature
Fusion Soft Installation and Operation Manual
2®
Fusion Soft Vessel and Flow/Temperature/Salinity Sensor
2
WARNING
CAUTION
Salinity
Studs
Flow/Temp/Salinity Sensor Face must
be clean at all times for proper operation
Fusion Soft vessel. The
2
Sometimes
Not Covered
Temperature
Sensors
Page 19