7.
Level the control/power center and tighten all screws, ensuring that the control/power center is securely fastened
to the mounting surface.
8.
Check source voltage. (All units are factory wired for 240 VAC).
factory wiring of the power center must be changed. (see Figures 11 and 13).
3.8

Grounding and Bonding

A solid, copper # 8 awg (8.4 mm
ground connection that is acceptable to the local inspection authority. Refer to your local codes for the acceptable
grounding wire gauge.
The National Electric Code (NEC) requires pool equipment to be bonded to each other. Check your local codes to
determine if the NEC and/or other local installation codes are enforced by the Authority Having Jurisdiction (AHJ).
A solid, copper # 8 AWG (8.4 mm
bonding connection that is acceptable to the local AHJ. Refer to your locally enforced codes for the acceptable
bonding wire gauge. Attach the bonding point located on the bottom of the chassis backplate to a common earth
bonding point. Do not use the power pack as the common bonding point. Each piece of non-related pool equipment
requiring a ground should also be bonded to the common, approved earth bonding point. Never ground a pool pump
to the chassis backplate.
3.9
Model Re-Confi guration
The Nature
2
Fusion Soft power interface board is confi gured as a Nature
If installing a Nature
Fusion Soft 700 model the power interface board MUST be re-confi gured.
2
To confi gure the board as a Nature
Figure 8.
If the power interface board is not re-confi gured, the life of your Nature
Heat Sink
L-Bracket
Chlorine Generator
Power Interface Board
Figure 8.
Chlorine Generator Power Interface Board
Nature
Fusion Soft Installation and Operation Manual
) wire is recommended for connecting the control/power center to a permanent earth
2
2
) wire is recommended, per the NEC, for bonding the power pack to a permanent

IMPORTANT

2
Fusion Soft 700 model, use cutting pliers to cut the JL1 jumper as shown in
In order to use on 120 VAC, the internal
2
Fusion Soft 1400 model by factory default.
CAUTION
Fusion Soft will be shortened.
2
Page 17
Cut JL1 Jumper to configure
board as a Nature
2
Fusion
Soft 700 Model