Electrical Specifi Cations; Circuit Protection - Nature2 Fusion soft Serie Manual De Instalación Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.4
Electrical Specifi cations

Circuit Protection

If only the Nature
devices are connected to the circuit breaker use a 20 AMP fuse at the electrical panel.
Nature
Fusion Soft 700 Connected to FUSIONM
2
Input
120 VAC, 50/60 Hz, 1.5 AMPS
240 VAC, 50/60 Hz, 0.75 AMPS
Output
22-30 VDC @ 3 AMPS maximum
Chlorine
0.625 lb / day (283 gm / day)
External
ORP/External Control Connector
Control
AquaLink
RS485 Connector
®
Option
The FUSIONM saltwater chlorinator electronics are factory wired for 240 VAC service. If the available
electrical service is 120 VAC, then the power supply wiring must be changed to operate on 120 VAC as shown in
Figures 11 and 13.
The chlorinator electronics are powered from the LOAD SIDE of the pool circulation pump relay; therefore, if the
available electrical service is 120 VAC, then the pump must also be wired for 120 VAC.
Nature
Fusion Soft Installation and Operation Manual
Fusion Soft is connected to the circuit breaker, use a 5 AMP fuse. If more
2
Nature
Fusion Soft 1400 Connected to FUSIONM
2
120 VAC, 50/60 Hz, 2.5 AMPS
240 VAC, 50/60 Hz, 1.25 AMPS
22-30 VDC @ 6 AMPS maximum
1.25 lb / day (567 gm / day)
ORP/External Control Connector
AquaLink RS485 Connector
CAUTION
Page 9