3.12.2 Connection of PureLink
Jandy
AquaLink
®
The chlorine generator electronics in the PureLink power center and the AquaLink RS controller require a four (4)
wire connection to communicate. Any outdoor rated four (4) conductor cable, minimum 22 AWG, can be used. Locate
the appropriate screw terminals on the circuit board according to Figures 16a and 16b. Wire the chlorine generator
power interface board from the red 4-pin terminal bar to the AquaLink RS red 4-pin terminal bar. See Figure 16a.
Wire the PureLink power center transformer to the load side of the fi lter pump relay. See Figures 12 and 13.
Chlorine Generator
Power Interface Board
PureLink
Power Center
Figure 16a. Wiring a PureLink Control System
Network
Nature
Fusion Soft Installation and Operation Manual
2®
Chlorine Generator Electronics to a
TM
RS
®
Red, 4-Pin
Terminal Bar
4 3 2 1
TM
All Button
OneTouch
or
PDA
Transceiver
J-box for PDA
Figure 16b. Wiring a PDA Control System Network
Red, 4-Pin
Terminal Bar
4 3 2 1
PureLink
Power Center