DAILY BRAZIER:
Through a mechanical system, the burn pot is cleaned at set intervals automatically by the boiler. In the picture below one
can see the burn pot with the opening underneath it.
It is in any case recommended to remove any ash residue using a vacuum cleaner, at least once every 2 days.
DAILY SCRAPERS:
HSYSTEM 15/22: The heat exchangers must only be cleaned
when the generator is cold! Cleaning the heat exchangers
allows to ensure constant heat output over time. This type of
maintenance must be performed at least once a day. To do
this, just use the relevant scrapers positioned in the upper
part of the generator, making the upward movements and
vice versa several times.
HSYSTEM 30: The cleaning of the heat exchangers is carried
out automatically using a mechanical system that allows to
guarantee over time constant heat output.
WEEKLY COMBUSTION CHAMBER AND THE
ASH TRAY:
It is recommended to remove the ash in the combustion
chamber at least once a week using a suitable vacuum
cleaner.
To facilitate cleaning, we recommend the activation of the
"CLEAN COMBUSTION CHAMBER" See chapter
FUNCTIONS.
Empty the ash drawer every week or when required.
76