18.15 MANUAL TUNE Display Page.

This display page is for making some small adjustments to the L-C values of the
automatic tuner; this "fine tune" operation could be necessary either if the user cannot
reach a good match using the automatic tuning or if he simply wants to apply some
manual variations to the current settings.
In the following picture is shown an example of some settings of the Manual Tune
Display Page together with the Status Bar readouts that allow total control of the
situation; it can easily seen that Input 1 is used in the 160 m band with antenna 2
connected and with the sub-band 6 (1.840 MHz..1.850 MHz) switched.
The two "sliders" L-C (Lout, Cout) position is:
• 8.2 uH for Lout
• 1436.9 pF for Cout
Using the following keys:
• [◄L] [L►]
• [◄C] [C►] the resulting value of Cout may be changed (-/+)
All the changes are shown using the "sliders" graphics shown on the display page:
Manual de usuario
[SET]
the resulting value of Lout may be changed (-/+)