Operating Instructions SATA RCS
EN
Clean the SATA clean RCS at regular intervals and check for leaks.
13. Malfunctions
Malfunction
Poor cleaning results
Too much cleaning so-
lution, high consump-
tion rate of cleaning
agent
14. After Sales Service
For accessories, spare parts and technical support, please contact your
local SATA dealer.
15. Accessories
Art.
Description
No.
147082 Earthing cable
3 m long
13870
Spray air hose,
blue, 9 mm, 1
m long
112
Cause
Tank with clean
cleaning agent
is empty.
Not enough intake
pressure.
Intake hose clogged or
buckled.
Not enough cleaning
solution (only for SATA
clean RCS the turbo
cleaner).
Intake pressure is too
high.
Incorrect setting
of pressure regula-
tor (only for SATA
clean RCS the turbo
cleaner).
SATA
SATA
clean RCS
clean RCS
micro
compact
x
x
x
x
Corrective Action
Fill the tank or put a
new tank in position.
Ensure intake pressure
as per technical data
(see chapter 7).
Make sure the intake
hose is clear.
Adjust the flow of
cleaning solution (see
chapter 10.3).
Ensure intake pressure
as per technical data
(see chapter 7).
Adjust the flow of
cleaning solution (see
chapter 10.3).
SATA
clean RCS
the turbo
cleaner
x
x
1 pc.