If any faults are observed during the installation, the supplier should be notified immediately for the
5.1.3.1 Configuration of machine voltage.
The voltage configuration of the machine is stipulated on the nameplate. If the mains voltage supply is not
the same as that stipulated on the machine, it has a terminal box from which the different voltage options
can be configured (230V 1N, 230V 3 or 400V 3N). In the event of a change, the supplier must be notified to
ensure that the machine's guarantee remains valid. To access the terminal holder, undo the front panel
(See figures 1, 2, 3).
a m /
v e
a
n , m ,g
g
m
n
Figure 3 400 V 3N Connection
41
asberprofessional.com
An easily accessible switch device should be installed next to the appliance for all the phases, with
a minimum gap of 3 mm between contacts. This switch should be used to disconnect the appliance
during installation, repair, cleaning and maintenance work. The switch should have fuses suitable
for use with the rated current (A) of the machine. Alternatively, a suitable magneto-thermal switch
may be used.
The appliance must be earthed using a differential protector. The manufacturer will not be held li-
able for damage originated by failure to observe this requirement.
subsequent analysis of the machine.
THE MANUFACTURER WILL NOT BE HELD LIABLE FOR ANY PERSONAL OR MATERIAL
DAMAGE TO THE MACHINE RESULTING FROM THE INCORRECT INSTALLATION ORIGINATED
BY FAILURE TO COMPLY WITH THE MANUFACTURER'S SPECIFICATIONS.
ONLY AUTHORISED PERSONNEL may change the electrical
configuration. Users may not tamper with the machinery.
M
N
T
S
R
am/
ve
M
a
g
m
n
Figure 2 230 V 3 Connection
ENGLISH
am /ve
M
a
g
n
n ,m ,g
m
n ,m ,g
Figure 1 230 V 1N Connection