7.2 Errors shown in display.
The following table lists the error warnings that may be displayed.
ER‐
RORS
ON/OFF LED lights up for 0.5 s and turns off for 2
E1
seconds, repeatedly.
ON/OFF LED lights up twice for 0.5 s each time and
E2
turns off for 2 seconds, repeatedly.
ON/OFF LED lights up three times for 0.5 s each time
E3
and turns off for 2 seconds, repeatedly.
ON/OFF LED lights up four times for 0.5 s each time
E4
and turns off for 2 seconds, repeatedly.
ON/OFF LED lights up five times for 0.5 s each time
E5
and turns off for 2 seconds, repeatedly.
56
asberprofessional.com
DETECTION
DENOMINATION
Door or hood is open.
Incorrect water level. Stipulated fill time ex‐
ceeded.
Incorrect drainage of the machine Stipulated
drainage time exceeded.
Incorrect boiler temperature. Stipulated boiler
heating time exceeded.
Incorrect tank temperature. Stipulated tank
heating time exceeded.