General Troubleshooting (Always Check the Status LED Light)(Continued)
Problem
Remote Control has less
than 25' operating range
Opener works from Wall
Control, but not from
Remote Control
Noisy operation
Safe-T-Beam® System
Door closes, and Opener
shuts down
W
D
IRING
IAGRAM
WARNING
WALL CONTROL
WHITE
WHITE
OPEN LIMIT
CLOSE LIMIT
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
• Relocate Remote Control inside car.
• Ensure Remote Control is pointing toward garage door when pressing Control Button.
• Replace Remote Control Battery
• Reposition Opener Antenna Wire.
• Do Not attempt to retune Remote Controls or Receiver.
• Program code for each Remote Control into Receiver memory (See Programming the Remote
Control on page 22.
• Replace Remote Control Battery
• Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses.
• Check Safe-T-Beam® System for any diagnostic codes. If present, troubleshoot as detailed in
Safe-T-Beam® System Self-Diagnostic Troubleshooting Chart (See page 24).
• Ensure all fasteners are tightened.
• Check that the garage door and Opener are in good repair, properly lubricated, and properly
balanced. (See Maintenance page 23).
• WARNING: If you suspect a problem with garage door hardware or springs, contact a Genie
Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE.
If an operational problem exists, Opener will not run closed.
•
• Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses.
• Check Safe-T-Beam® System for any diagnostic codes. If present, troubleshoot as detailed in Safe-T-Beam®
System Self-Diagnostic Troubleshooting Chart (See page 24).
• Check position of Wall Console Vacation Lock Switch. It must be in UNLOCKED position for Opener to
open door.
Opening Cover May Result in Electric Shock
CONTROLLER BO ARD
What To Do
type "A23." (See page 22).
type "A23." (See page 22).
GREEN
PRIMARY GROUND
MOTOR DRIVE BOARD
GREEN
LINE
PLUG
BLACK
WHITE
LIGHTS
WHITE
(60 WATTS MAX.)
BLUE
MOTOR
27