7.4 Troubleshooting
Fault
Not all fumes are
captured.
Signal horn
sounds
Dust comes out
on clean air side.
Device does not
start.
7.5 Emergency measures
The following measures may be helpful in the event of a fire in the MaxiFil:
Inform the responsible fire safety officer and follow their instructions.
-
If necessary, Inform the local fire brigade.
-
If possible, disconnect the MaxiFil from the mains by pulling the plug or have
-
an instructed specialist (electrician etc.) disconnect the electrical power supply
for the MaxiFil at the upstream local sub-distributor.
If necessary, Fight fire with commercially available dry powder extinguisher.
-
Attention!
Flash flame formation, hazardous fumes and smoke occur in the event of a fire which
may lead to suffocation. If possible, wear personal protective equipment.
KEMPER MaxiFil stationary - operating instructions- EN
Possible cause
Distance of extraction hood to welding
site too large.
Blow-off covered up.
Extraction performance too low,
throttle valve in the extraction hood
closed.
Filter element saturated.
Filter element is damaged.
Lack of voltage.
Start-stop sensor connected, however,
no power detected (no welding
happening yet)
Technical modifications and errors expected.
- 85 –
Solution
Move extraction hood
closer.
Keep blow-off
uncovered.
Open throttle valve in
extraction hood fully.
Change filter element.
Change filter element.
Have it checked by an
electrician.
Start welding process