Operating instructions SATAjet 1000 K (RP/HVLP), H RP
4.4 Correct adjustment of the dynamic inlet pressure
a) Spray gun with micrometer / gauge
Ensure sufficient pressure by means of the pressure regulator. Adjust the
recommended inlet pressure of 1,5 - 2,0 bar/22 - 29 psi at the micrometer.
Art. No. 27771
b) Spray gun equipped with compressed air control gauge
Adjust the pressure at the pressure regulator in a way that the spray gun
inlet pressure required for the respective gun model is obtained.
Art. No. 4002
c) Spray gun without gauge
In order to make a correct adjustment of the spray gun inlet pressure, as
otherwise measureable in a) to b), without a gauge, adjust a pressure of
about 9 psi higher per 10 m to inlet pressure to compensate the pressure
drop in the hose.
4.5 Material flow control
Adjust material flow control
in accordance with spray viscosity and required flow rate (arrow 1 ) and fix
by means of the counter nut (arrow 2 ). Under normal circumstances, the
material flow control is fully open.
4.6 Round/flat spray control
Round/flat spray control for right-handed painters
for infinitely variable adaptation of the spray fan to the object:
Turn to the left - flat spray
Turn to the right - round spray
IX.4
2
1