4.4. ADJUSTING THE BALANCE SPRING
IMPORTANT!: The barrier is supplied already balanced for
the exact beam length specified in the order (see the
Barrier Order Specifications, in the price list, and TAB. 2 - 3)
Should a fine adjustment of the beam balance be needed,
proceed as follows:
1) Unlock the operator, as indicated in paragraph 6 .
TAB. 2
BALANCE SPRING FOR RIGID BEAMS
BARRIER
BEAM
MODEL
LENGTH
(m)
1.50 - 2.24
2.25 - 2.74
620 STANDARD
2.75 - 3.24
620 RAPID
3.25 - 4.00
3.75 - 4.24
4.25 - 5.24
640 STANDARD
5.25 - 6.74
6.75 - 7.00
TAB. 3
BALANCE SPRING FOR BEAMS WITH SKIRT
BARRIER
BEAM
MODEL
LENGTH
(m)
2.00 - 2.99
3.00 - 3.74
620 STANDARD
3.75 - 4.00
3.75 - 4.74
4.75 - 5.24
5.25 - 5.74
640 STANDARD
5.75 - 6.74
6.75 - 7.00
DIAMETER OF
SPRING
SPRING WIRE
LENGTH
(mm)
(mm)
4.50
400
5.50
400
6.00
400
7.30
400
7.00
400
8.00
400
9.00
400
10.50
460
DIAMETER OF
SPRING
SPRING WIRE
LENGTH
(mm)
(mm)
5.50
400
6.50
400
7.00
400
8.00
400
10.00
460
10.50
460
11,00
460
12.00
460
2) Adjust the pre-loading ring nut, using the spanner
supplied, as shown in Figure 12.
The beam is correctly balanced when it remains steady
in the 0° e 90° positions.
If the beam tends to close, turn the ring nut clockwise.
If it tends to open, turn the ring nut counterclockwise.
5. START-UP
5.1. CONNECTING THE ELECTRONIC UNIT
Important! Disconnect the power supply before you perform
any type of operation (connections, programming or
maintenance) on the electronic unit.
Warning: When terminal strip J2 is disconnected, the power
supply outputs of the motor, fan and flashing lamp are still
connected to electric power.
Follow points 10, 11, 12, 13 and 14 of the GENERAL SAFETY
REGULATIONS.
Position the pipes, as shown in Figure 3, and connect the
624 MPS electronic unit to the accessories.
Keep the power supply cables separate from the control
Fig. 11
and safety signal ones (photocells, receiver, pushbutton,
etc.). To prevent electric interference, use separate pipes.
TAB. 4 TECHNICAL CHARACTERISTICS OF 624 MPS
POWER SUPPLY
MAX. MOTOR LOAD
MAX. ACCESSORY LOAD
MAX. WARNING LIGHT POWER
TEMPERATURE RANGE
Fig. 12
TAB. 5 OPERATION OF STATUS LEDS
LED
FCC
SPRING
FCA
CODE
OPEN
CLOSED/FSW activated (*)/saf. disengaged(**) deactivated (*)/saf. engaged (**)
721085
STOP
721069
ALARM
721070
WARN. LIGHT
721072
POWER
721073
(*) P logic operation
721074
(**) A / E logic operation
721075
721080
TAB 6 CURRENT DRAWN BY ACCESSORIES
ACCESSORY
SPRING
R 31
CODE
PLUS 433 E
MINIDEC SL / DS
721069
DECODER SL / DS
721071
RP 433 ESL / EDS
721073
DIGICARD
721074
METALDIGIKEY
721079
FOTOSWITCH
721080
DETECTOR F4 / PS6
721081
721082
MINIBEAM
16
230 V (+6 -10 %) 50 Hz
ON (contact closed)
closing limit switchnot engaged
opening limit switchnot engaged
activated
deactivated
beam moving
see warn. light operation
motor power on
NOMINAL CONSUMPTION
300 W
500 mA
5 W (24 Vac)
- 20°C to 55°C
OFF (contact open)
closing limit switch engaged
opening limit switch engaged
deactivated
activated
beam stationary
see warn. lightoperation
motor power off
50 mA
20 mA
6 mA
20 mA / 55 mA
12 mA / 6 mA
15 mA
15 mA
90 mA
50 mA
70 mA