56 | EPS 118 | Safe handling
4.1.1
Use of the EMERGENCY STOP switch
Only use the EMERGENCY STOP switch in case of
emergency.
4.1.2
During repair work
When performing any work, follow the instructions
for switching on and off in the operating instructions
along with the servicing instructions!
Component parts and larger assemblies are
to be carefully attached to lifting gear on re-
placement and secured to avoid any hazards.
Only use suitable lifting gear in proper wor-
king order and loadbearing elements with
an adequate capacity. Never stand or work
under suspended loads.
Fit and check the safety systems immediately fol-
lowing completion of servicing and repair work.
Always re-tighten bolted joints to the specified
torque after servicing and repair work.
|
1 689 989 300
2020-03-24
4.2
High-pressure hoses
!
The high-pressure hose is a safety component
which must be replaced if damaged. High-pressure
hose repair is not permissible. Also, the high-pres-
sure hose assembly must be replaced after 2 years
from the date of manufacture at the latest.
Always check the high-pressure hose for external
damage prior to connection.
The high-pressure hose must be replaced in the
following situations:
$
Union nuts stiff.
$
Sealing cones deformed or damaged.
$
Cracks, brittle areas, blistering and leakage at
the hose jacket.
$
Leakage at the hose fittings.
Never twist the high-pressure hose as torsion could
damage the hose inlays.
Ensure large bending radius when connecting the
high-pressure hose, as small bending radii reduce
the cross-section. The smallest permissible ben-
ding radius is r = 90 mm.
The bending radius should not start at the fitting
holder but rather approx. 20 mm away from it.
On connection, make sure the high-pressure hose
cannot come into contact with other hoses or
objects during operation. Vibration may lead to
abrasion at contact points.
Always comply with the specified tightening torque
when connecting the high-pressure hose.
Replace the high-pressure hose every 2 years. The
reference date is the date of manufacture on the
high-pressure hose.