Alarm Operation - Astralpool Corail protect Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.1.3 BUZZER
System status
Normal operation
Monitoring alarm
Mains power supply failure
Infrared beacon cut off(fog, frost)
Battery charge fault
Cut-off/sort-circuit on a wiring link between
system elements
Beams cut off or blocked in the case of an attempt
to activate the monitoring manually using the
buttons on the control unit
Comment: Slow flashed = Come on once every 2 seconds
6.2 ALARM OPERTION
6.2.1
MONITORING Alarm :
The monitoring alarm is triggered if one of the beams is cut off while the monitoring system is activated.
Triggering of the:
-
Integrated siren with continuous, modulated tone at a high level (~100dBA)
-
Remote control buzzer
-
Exterior alarm sirens if fitted
-
Monitoring LED with flashing that continues until the monitoring system is deactivated or
switched to Off mode using the key operated switch.
Note: In the event that the intrusion alarm sounds, all the sirens (internal or external) are activated for 1
min 30. It is possible to stop the alarms either by pressing one of the buttons on the remote control, or by
turning the key in the key-operated switch. Attention: in this last case, the system switched to all off
mode.
6.2.2
TECHNICAL FAILURE alarm:
The technical failure alarm is triggered in the event of:
-
An internal system supply fault(other than a mains power failure)
-
A battery charge fault
-
Occultation of an infrared beacon(fog,frost,obstacle,etc) if the monitoring system is
activated
-
A fault in the wiring links between elements
-
A self-monitoring alarm for the sirens
Triggering of:
-
The integrated siren generating 2 cyclical medium-level beeps (~80 DBA) repeated every 30 sec,
until the alarm is dealt with or the key-operated switch is set to OFF, with a repeat on the control
unit buzzer.
-
Exterior failure alarm sirens, if fitted, using the same operating mode as the integrated siren.
Buzzer status
Silent
Sounds continuously
2 cyclical beeps every 30 sec until the problem has
been dealt with or the key operated switch has
been set to off mode, without repeat on the
integrated or remote sirens deportees
2 cyclical beeps every 30 sec until the problem has
been dealt with or the key operated switch has
been set to off mode, with repeat on the integrated
or remote sirens deportees
Repeated beeps as long as the buttons are pressed
Quick flashes= Comes on 5 times per second
versión 1-2008
31