5.4 AUTOMATIC RESETTING OF THE MONITORING MODE
It is necessary to reactivate the monitoring mode manually when leaving the poolside. Nonetheless, if this
is not done, they system reactivates the monitornig mode automatically after a time delay. The time delay
is set by the installer when the system is installed (factory setting 2 min). It is possible to set the time
delay to: 2 min (for testing only), 30 min, 1 h 30, 2 h, 2 h 30, 3 h or 3 h 30. The time delay is reset to zero
each time a beam is cut off (use of the pool). We can thus consider that the time delay starts as from the
time at which the pool is no longer used, i.e. after the last beam cut-off sequence.
A series of increasingly fast warning beeps is sounded on the integrated siren, and the remote control
buzzer, 60 s before the automatic reset sequence. To restart the time delay sequence, all that is required is
to cut one of the beams or press one of the buttons on the control unit.
6.
TROUBLESHOOTING
6.1 LED OPERATION ON THE REMOTE CONTROL
6.1.1
CONTROL LET
System status
Normal operation
Mains power supply failure
Infrared Beacon cut off (fog, frost, obstacle, etc.)
Battery charge fault
Internal system power supply fault
Cut-off/short-circuit on a wiring link between
system elements
6.1.2 MONITORING LED
System status
Monitoring activated
Monitoring deactivated
Monitoring alarm memorized
Indicator status
On steadily
Flashes slowly until the problem has been dealt
with or the key operated switch has been set to off
mode
Flashes quickly until the problem has been dealt
with or the key operated switch has been set to off
mode
2 cyclical flashes until the problem has been dealt
with or the key operated switch has been set to off
mode
3 cyclical flashes until the problem has been dealt
with or the key operated switch has been set to off
mode
4 cyclical flashes until the problem has been dealt
with or the key operated switch has been set to off
mode
Indicator status
On
Off
Flashes quickly until the next deactivation of the
monitoring system (pressing butoons A and B on
the control unit at the same time)
versión 1-2008