Operating instructions SATAminijet 1000 K/H RP/HVLP
Description
Weight with 1 l aluminium cup
SATAminijet 1000 H

8. Operation

Warning!
Risk of injury from bursting compressed air hose
If an unsuitable compressed air hose is use, it can be damaged by too
much pressure and explode.
→ Only use solvent-resistant, antistatic and technically flawless hose for
compressed air with permanent pressure resistance of 10 bar, bleeder
resistance of < 1 MOhm and min. inner diameter of 9 mm (see chap-
ter 14).
Warning!
Risk of injury from excessive material input pressure
Excessive material input pressure can cause bursting of the material
hose and other components conveying material.
→ The material input pressure stated on the gun may not be exceeded.
Attention!
Damage from dirty compressed air
Using soiled compressed air can cause malfunctions
.
→ Use clean compressed air. For example with SATA filter 100
(# 148247) outside the spray booth or SATA filter 484 (# 92320) inside
the spray booth.
Before using the spray gun, heed / check the following points to warrant
safe working:
■ Screws [2-1], [2-2], [2-3], [2-4] and [2-5] fit firmly. Tighten screws if
necessary.
■ Fluid tip [2-2] tightened with a torque of 12 Nm [7-5].
■ Locking screw [10-1] tightened.
■ Technically clean compressed air is being used.

8.1. First Use

■ Blow through the compressed air pipe thoroughly before installation.