OPERATION IN AIR DUCTING WITH NTC PROBE 10K
SET con gured to OFF
Set the desired temperature ( from 7 to 37 °C)
SET con gured to AUTO
Set the desired temperature ( from 7 to 37 °C)
SET con gured to COMFORT
Set the desired temperature ( from 7 to 37 °C)
TA ADDITIONAL THERMOSTAT OPTIONAL
The appliance is able to control the room temperature through an additional thermostat (optional).
After ignition (by pressing key 1 or in chrono mode), the stove will work to reach the set value on the thermostat, displaying WORK (closed
contact) on the screen. The on-board ambient probe will automatically be ignored.
TO INSTALL AND ACTIVATE:
A mechanical or digital thermostat is required.
Remove the plug from the socket.
Using the image to the side as a guide, connect the two thermostat wires (clean contact - no 230 V!)
to the respective terminals at the back of the machine, one red and the other black.
Connect the power to the stove again.
The stove is now correctly con gured.
It will work by checking the external additional thermostat based on the TA function.
FOR CORRECT OPERATION SET
THE AMBIENT SET THERMOSTAT TO LOW TA
INSTALLATION MUST BE PERFORMED BY QUALIFIED STAFF AND/OR THE MANUFACTURER'S SERVICE TECHNICIANS
FUSE
If there is no power supply to the stove, check the
state of the fuse located in the box between the
stove switch and the power cord connection.
48
OPTIONAL
The air ducting motor will remain o unless the fumes temperature exceeds the
normal operating temperatures
Once the speci c activation threshold has been reached and exceeded, at temperature
to be satis ed the air ducting motor will follow the stove settings.
When the temperature set in TEMPERATURE is reached, the air ducting motor will
switch OFF and switch on again when there is a new request.
Once the speci c activation threshold has been reached and exceeded, at temperature
to be satis ed the air ducting motor will follow the stove settings but at a lower speed
than in SET AUTO for increased acoustic/ambient comfort.
When the temperature set in TEMPERATURE is reached, the air ducting motor will
switch o and switch on again when there is a new request.
SAME OPERATING SETTINGS FOR AIR DUCTING 2 MOTOR